| Date |
Text |
| 2003-06-04 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03051430 |
| | ADD: 4225 45TH ST |
| | CONT: CODE ONE GROUP |
| | TEL: (954)370-2302 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | ACTION: DENIED |
| | |
| | TIE DOWN PERMITS: |
| | 1) 030514305) 03051437 |
| | 2) 030514346) 03051438 |
| | 3) 030514357) 03051439 |
| | 4) 03051436 |
| | |
| | 1) THE PERMIT APPLICATION SUBMITTED FOR |
| | THE ABOVE LISTED PERMITS IS DEFICTENT IN |
| | REQUIRED INFORMATION THE DEPARTMENT OF |
| | HIGHWAY SAFETY & MOTOR VEHICLES, DEVIS- |
| | ION OF MOTOR VEHICLES, BUREAUOF MOBILE |
| | HOME AND RECREATIONAL VEHICLE CONSTRUCTI |
| | ON. |
| | FLORIDA STATUTES REQUIRES THATMOBILE/ |
| | MANUFACTURED HOMES ARE INSTALLED SAFELY |
| | AND WILL MEET WIND LOADS AS DETERMINED |
| | BY PART 3280, MANUFACTURED HOME CONSTRUC |
| | TION AND SAFETY STANDARDS, FEDERAL REGUL |
| | ATIONS HOUSING & URBAN DEVELOPMENT. |
| | IT IS THE RESPONSIBILITY OF THE |
| | MOBILE HOME & RECREATIONAL VEHICLE |
| | CONSTRUCTION TO REGULATE THESE INSTALLAT |
| | IONS, ASWELL AS THE MATERIAL USED, FOR |
| | ALL NEW AND USED HOMES. |
| | THE STATE HAS A LIST OF APPROVED AN- |
| | CHORS AND COMPONENTS FOR INSTALLATION. |
| | |
| | 2) FLOOD ZONE A-8 REQUIRED ELEVATION OF |
| | 15'-0" TO THE LOWEST FLOOR OF THE MOBILE |
| | HOME, TO BE AT OR ABOVE THIS ELEVATION. |
| | CITY CODE SEC. 94-546(4). |
| | |
| | 3) AREAS OF SHALLOW FLOODING: ATTENDANT |
| | UTILITIES (A/C COMPRESSOR, ELEC HOOK UP) |
| | AND SANITARY FACILITIES, TO BE COMPLETE- |
| | LY FLOOD PROOFED TO OR ABOVE THAT LEVEL |
| | SO THAT ANY SPACE BELOW THAT IS WATER- |
| | TIGHT. CITY CODE 94-546.(C) |
| | |
| | 4) CITY CODE 94-546.3 MOBILE HOMES, |
| | ALL COMPONENTS OF THE ANCHORING SYSTEM S |
| | HALL BE CAPABLE OF CARRYING A FORCE OF |
| | 4,800 POUNDS. |
| | |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | (561) 805-6715 |