| Plan Review Notes For Permit 03051279 |
| Permit Number |
03051279 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-05-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS. | | | A) SECTION 909.1 ONLY FIXTURES OF THE | | | BATHROOM GROUP SHALL DRAIN INTO THE WET | | | VENT FOR THE BATHROOM. - TIE LAUNDRY | | | SINK DOWNSTREAM OF BATHROOM FIXTURES. | | | B) MINIMUM SIZE PIPE FOR WASHMACHINE IS | | | 2". TABLE 709.1 - CLEANOUT REQUIRED MIN. | | | 4' ABOVE FINISHED FLOOR AT W/MACHINE. | | | C) MINIMUM SIZE TRAP FOR LAUNDRY SINK IS | | | 1-1/2" PER TABLE 709.1. | | | ---SEE RED LINE CORRECTIONS ON PLANS AND | | | MAKE CORRECTONS TO PLANS AND RESUBMIT. | | | D) FLA. STATUTES 61G1-16.004 MINIMUM | | | INFORMATION REQUIRED, FIRM LICENSE NUM- | | | BER REQUIRED ON EACH SHEET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|