2003-05-22 00:00:00DENIED:MECHANICAL PERMIT 03050949
  
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW:
  
 1.PROVIDE ENERGY & MANUAL J CALCS AS
 PER 2001 FBC CHAPTER 13 SUB-SECTION 600.
  
 2.INDICATE IF A/C EQUIPMENT IS NEW
 OR EXISTING.PROVIDE MAKE, MODEL, BTU
 OF THE AHU & SEER OF THE C.U.
  
 3.PROVIDE SQUARE FOOTAGE OF EXISTING
 & SQUARE FOOTAGE OF THE ADDITION.
  
 4.PLEASE NOTE, EXHAUST FAN REQUIRED IN
 THE NEW BATHROOM AS PER 2001 FBC(M)
 402.2.SHOULD TOILET ROOM BE SEPARATED
 FROM BATH AREA BY A DOOR, AN EXHAUST FAN
 WILL ALSO BE REQUIRED FROM THE TOILET
 ROOM AS PER 2001 FBC(M) 502.13.
  