| Plan Review Notes For Permit 03050835 |
| Permit Number |
03050835 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-05-12 00:00:00 | MASTER PLAN 02080925 MODEL "E" | | | 1609.4.3 LOAD REDUCTION. | | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | | 1609.4.1 OR 1609.4.2, THE COMBINED | | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | | FROM THE LOAD COMBINATION OF THE DEAD | | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | | CODE OR A REFRENCED STANDARD SHALL NOT | | | BE USED WITH THESE LOAD COMBINATIONS | | | EXCEPT THAT A DURATION OF LOAD INCREASE | | | SHALL BE PERMITTED IN ACCORDANCE WITH | | | CHAPTER 23. | | | | | | RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE | | | FOOR FRAMING INSPECTION. | | | JIM WITMER | | | (561)805-6715 |
|