| 2003-12-18 00:00:00 | *****CORRECTIONS****** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)THE HANDRAIL DETAIL ON SHEET A1.1 |
| | IS TO COMPLY WITH 1608.2.1. |
| | |
| | 2.)INCLUDE A TITLE BLOCK ON SHEETS |
| | FS1,FS2,FS3 AND SEAL THE CONCRETE FLOOR |
| | SYSTEM SHEETS, FS61G15-23.002. |
| | |
| | 3.)SEE THE PREVIOUS LIST, HOW WILL |
| | THE #4@12" OC TERMINATE IN THE B1 BEAM |
| | FOR THE BALCONY SHOWN ON SHEET S1.1? |
| | NOT ADDRESSED. |
| | |
| | 4.)SEE THE PREVIOUS LIST IN REGARDS |
| | TO THE BALUSTRADE DETAIL.EMBEDMENT AT |
| | THE TOP WAS GIVEN BUT NOT EMBEDMENT AT |
| | THE BOTTOM.SEE 1608.2.2 FOR MINIMUM |
| | DESIGN LOADING AND PROVIDE SUPPORTING |
| | CALUCLATIONS TO DEMONSTRATE COMPLIANCE |
| | WITH SAME.SEE ALSO FBC1015 FOR MINIMUM |
| | GUARDRAIL DIMENSIONS AND NOTE SAME IN |
| | THE DESIGN CRITERIA. |
| | |
| | 5.)THE ENERGY CALC TOTAL SQUARE |
| | FOOTAGE DOES NOT APPEAR TO BE THE SAME |
| | AS THE A/C AREA ON THE PLAN.ADDRESS. |
| | |
| | 6.)WHEN MAKING CHANGES, IN ORDER TO |
| | EXPEDITE PLAN REVIEW, CLEARLY CLOUD AND |
| | NUMBER ALL REVISIONS.SUBMIT OLD SHEETS |
| | (APPROVED ZONING AND IMPACT FEE STAMP |
| | ARE NOT ON THIS SET AND ARE REQUIRED |
| | BEFORE THE PERMIT CAN BE ISSUED). |
| | |
| | 7.)SUBMIT THE FOLLOWING PRODUCT |
| | APPROVALS: |
| | MULLIONS |
| | FIXED GLASS |
| | GLASS BLOCK |
| | |
| | 8.)NOTICE OF COMMENCEMENT IS EXPIRED |
| | (90 DAYS WITHOUT COMMENCING WORK), |
| | FS713.13. |