| Plan Review Notes For Permit 03050241 |
| Permit Number |
03050241 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-08-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHEET P.7.0.1 (PHE) SECTION 909.1 | | | ONLY THE FIXTURES WITHIN THE BATHROOM | | | GROUP SHALL CONNECT TO THE WET-VENTED | | | HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF | | | THE WET VENT.-BAR SINK SHALL DIS- | | | CHARGE DOWNSTREAM OF BATHROOM GROUP. | | | | | | 2) SHEET P.7.0.2 UNABLE TO LOCATE THE | | | REVISION ON THIS SHEET. INDICATE LOCAT- | | | ION OF REVISION BY CLOUDING AND DARTING | | | REVISION. | | | | | | 3) ALL CHANGES OF THE FLOOR PLAN SHALL | | | BE REFLECTED ON THE SANITARY RISER DIA- | | | GRAM FOR THIS UNIT. SUBMIT REVISION FOR | | | SANITARY RISER DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|