2003-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLA. STATUTES
  
 1) THE DATE THAT THE SIGNATURE AND SEAL
 IS AFFIXED AS PROVIDED HERIN SHALL BE
 ENTERED ON THE PLANS. 61G15-23.002(1)
 2) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS AND NUMBER ON EACH
 SHEET. A TITLE BLOCK WILL SATISFY THIS
 REQUIREMENT. 61G15-23.002(2)
 3) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. BATH #2 SHOWS A
 TUB NOT SHOWN ON FLOOR PLAN.
 4) BAR SINK SHALL NOT THROUGH THE WET
 VENT OF THE BATHROOM FIXTURES. 909.1
 TIE BAR SINK DOWNSTREAM OF BATHROOM FIX-
 TURES. (SEE RED LINE).
  