| Plan Review Notes For Permit 03050057 |
| Permit Number |
03050057 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-03-05 00:00:00 | PASSED/PROVISO | | | | | | | | | PLUMBING APPROVAL ONLY.SEPARATE PERMIT | | | REQUIRED FOR GAS. MORE INFORMATION WILL | | | BE REQUIRED WHEN APPLYING FOR PERMIT. | | | - SPECIFICATION SHEET FOR ADA ACCESSIBLE | | | SLIDING DOOR HARDWARE FOR DOOR AT ROOM | | | #104A REQUIRED AT TIME OF FINAL INSPECT- | | | ION. - | | | | | | | | | PLUMBING PROVISO | | | | | | SHT P7-3.01 WATER HAMMER ARRESTORS ARE | | | REQUIRED ON THE WATER SUPPLY PIPING FOR | | | THE WASH MACHINES. SECTION 604.9 LOCATED | | | PER PDI-WH 201 NEAR THE FIXTURES. | | | | | | SHT P7-3.01 FULL OPEN VALVES ARE | | | REQUIRED ON THE TOP OF ALL WATER | | | DOWN-FEED PIPES PER SECTION 606.1(4) | | | | | | SHT P7-3.02 CLEANOUTS ARE REQUIRED AT | | | THE WASH MACHINES MINIMUM 4' ABOVE THE | | | FLOOR FOR ACCESS. SECTION 708.10 |
|