| Plan Review Notes For Permit 03042702 |
| Permit Number |
03042702 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-06-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03042702 | | | ADD: 201 S NARCISSUS AVE | | | CONT: POOL PEOPLE | | | TEL: (954)972-6300 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PERMIT APPLICATION,DESCRIPTION OF PRO- | | | JECT INDICATES A SPA AND FOUNTAIN? THERE | | | IS NO INFORMATIONM FOR THE FOUNTAIN | | | EITHER LOCATION OR DETAIL SHEET. | | | | | | 2) PERMIT APPLICATION INDICATES USE OF | | | HEATER, FL ENERGY CODE,412.ABCD.2.4.2. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH ACOVER DESIGNED TO MINI- | | | MIZE HEAT LOSS. | | | | | | 3) 424.1.8.5 DECKS, POOLS OF LESS THAN | | | 120 SQ FT OF POOL WATER SURFACE AREA | | | SHALL HAVE A MINIMUM 4 FOOT WIDE UNOB-ST | | | RUCTED CONTINUOUS DECK AROUND A MINIMUM | | | OF 50 % OF THE POOL PERIMTER. DECK LESS | | | THAN 4 FOOT WIDE SHALL HAVE BARRIERS TO | | | PREVENT THEIR USE. DECKS SHALL NOT BE | | | MORE THAN 10" BELOW THE TOP OF THE POOL. | | | | | | 4) EFFECTIVE BARRIER 64E-9.010(1) | | | SPA POOLS SHALL MEET THE REQUIREMENTS OF | | | RULES 64E-9.001 THROUGH 64E-9.008, | | | F.A.C., UNLESS SPECIFICALLY INDICATED | | | OTHERWISE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)805-6715 |
|