2003-06-05 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03042702
 ADD: 201 S NARCISSUS AVE
 CONT: POOL PEOPLE
 TEL: (954)972-6300
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PERMIT APPLICATION,DESCRIPTION OF PRO-
 JECT INDICATES A SPA AND FOUNTAIN? THERE
 IS NO INFORMATIONM FOR THE FOUNTAIN
 EITHER LOCATION OR DETAIL SHEET.
  
 2) PERMIT APPLICATION INDICATES USE OF
 HEATER, FL ENERGY CODE,412.ABCD.2.4.2.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH ACOVER DESIGNED TO MINI-
 MIZE HEAT LOSS.
  
 3) 424.1.8.5 DECKS, POOLS OF LESS THAN
 120 SQ FT OF POOL WATER SURFACE AREA
 SHALL HAVE A MINIMUM 4 FOOT WIDE UNOB-ST
 RUCTED CONTINUOUS DECK AROUND A MINIMUM
 OF 50 % OF THE POOL PERIMTER. DECK LESS
 THAN 4 FOOT WIDE SHALL HAVE BARRIERS TO
 PREVENT THEIR USE. DECKS SHALL NOT BE
 MORE THAN 10" BELOW THE TOP OF THE POOL.
  
 4) EFFECTIVE BARRIER 64E-9.010(1)
 SPA POOLS SHALL MEET THE REQUIREMENTS OF
 RULES 64E-9.001 THROUGH 64E-9.008,
 F.A.C., UNLESS SPECIFICALLY INDICATED
 OTHERWISE.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)805-6715