| Date |
Text |
| 2003-07-22 00:00:00 | THIRD CHECKLIST: |
| | 1-ENERGY CALCULATIONS WERE NOT PROPERLY |
| | REVISED: ENERGY CALCULATIONS DON'T |
| | MATCH ORIENTATION OF THE HOUSE. ENERGY |
| | CALCULATIONS ARE TYPICALLY DONE TO |
| | WORST CASE SCENARIO WHEN BUILDING A |
| | MODEL OVER AND OVER TO COVER ALL |
| | ORIENTATIONS. THESE ENERGY CALCS ARE |
| | NOT DONE FOR WORST CASE, NEITHER ARE |
| | ARE THEY SITE SPECIFIC. THESE IS THE |
| | THIRD TIME THE SAME COMMENT WAS RAISED |
| | BUT IT HAS NOT BEING CORRECTED. |
| | 2-PROVIDE SOIL TEST REPORT. |
| | 3-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ROOF TILE (IT'S A SEPARATE PERMIT, BUT |
| | STILL IS PART OF SUBMITTAL PACKAGE). |
| | B)ENTRY DOORS WITH UPDATED DADE COUNTY |
| | REPORT WITH DADE COUNTY LOGO AT BOTTOM |
| | LEFT OF REPORT AND WITH LEGIBLE DWGS |
| | WITH DADE COUNTY RENEWAL STAMP. |
| | C)COMPLETE GARAGE DOOR REPORT WITH |
| | LEGIBLE DRAWINGS. |
| | D)SITE SPECIFIC ENGINEERING NEED SITE |
| | SPECIFIC INFORMATION. INFORMATION |
| | SUBMITTED FOR MULLIONS IS GENERIC. |
| | CLEARLY SPECIFY ON DRAWINGS ALL THE |
| | SPECIFIC COMPONENTS TO BE USED ON |
| | THIS PROJECT. MULLION SIZE, ANCHORS, |
| | DESIGN PRESSURES, ETC. |
| | ALSO, INDICATE ADDRESS OF PROJECT AND |
| | PROVIDE COMPLETE SITE SPECIFIC FORM AS |
| | DONE FOR OTHER SITE SPECIFIC WINDOWS. |
| | E)NEED PRODUCT APPROVAL FOR STRUCTURAL |
| | HEADER ABOVE SLIDING GLASS DOORS. SEE |
| | PLANS FOR SIZES. |
| | F)PROVIDE GLASS BLOCK PRODUCT APPROVAL |
| | WITH LEGIBLE DRAWINGS. |
| | |
| | 4-REVISE BOLT SIZE SPECIFIED FOR ANCHOR |
| | SHOWN ON DETAIL 10/A5. SEE SIMPSON |
| | HIGH WIND-RESISTANT CONSTRUCTION |
| | CATALOGUE WHICH IS THE ONLY SIMPSON |
| | CATALOGUE REVISED TO MEET SECTION |
| | 1609.4.3 FBC 2001. |
| | 5-REVISE GABLE END CONSTRUCTION DETAIL |
| | AT FAMILY ROOM AREA TO COMPLY WITH |
| | SEC. 2117.1.2 FBC 2001. |
| | **ALSO, CLARIFY DETAILS 2/A5 AND 6/A5 |
| | BECAUSE THEY DON'T APPLY TO THIS AREA. |
| | REVISE AS REQUIRED. SEC. 104.2.1.2 |
| | CITY AMENDMENTS TO FBC 2001. |
| | 6-OWES $774.32 FOR WESTERN EXPANSION |
| | FEES AND RADON FEES. |
| | ADDITIONALY, RE-SUBMITTAL FEES WILL |
| | BE ADDED. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT (561)805-6712. |
| | |
| | **NOTE: |
| | PLEASE INSERT ANY REVISED DRAWINGS INTO |
| | THE SETS AND REMOVE ALL DRAWINGS. |