Plan Review Notes
Plan Review Notes For Permit 03042197
Permit Number 03042197
Review Stop P
Sequence Number 1
Notes
Date Text
2003-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) MINIMUM DISTANCE FROM CENTER OF W/C
 TO CENTER OF ADJACENT FIXTURE. IT APP-
 EARS THAT THE MEASURMENT FROM THE CENTER
 OF THE WATER CLOSET AND THE LAV IS LESS
 THAN REQUIRED. PLEASE INDICATE MEASUR-
 MENT FROM SHOWER CURB TO EDGE OF DOORWAY
 SECTION 405.3.1 (30")
 2) PLEASE PROVIDE MANUF. INFORMATION FOR
 STEAM UNIT. MUST BE LISTED.
 3) EMERGENCY PAN REQUIRED FOR WATER
 HEATER, AND THERMAL EXPANSION CONTROL IS
 REQUIRED FOR WATER HEATER. PLEASE PRO-
 VIDE WATER HEATER DETAIL.
  