2003-05-29 00:00:00BUILDING REVIEW CHECKLIST:
 1-PAY IMPACT FEES. BRING BACK STAMPED
 DRAWINGS AND RECEIPT.
 2-RIGHT SIDE ELEVATION EXCEEDS THE MAX.
 % OF OPENINGS ALLOWED BY TABLE 600 FBC
 2001. REVISE AS REQUIRED.
 3-GUEST SUITE EGRESS WINDOW DOESN'T HAVE
 THE 24" CLEAR HEIGHT REQUIRED BY SEC.
 1005.4 FBC 2001. PRODUCT APPROVAL
 SUBMITTED IS FOR PGT WINDOWS. PGT DOES
 NOT HAVE A 24+5 SIZE WINDOW. SEE
 PRODUCT APPROVAL. IS THIS A CUSTOM
 MADE WINDOW? IF SO, THEN, PROVIDE THE
 MANUFACTURER CUT SHEETS.
 4-NEED RECORDED DEED SHOWING AT LEAST 3'
 EASEMENT ON NEIGHBOR'S PROPERTY TO
 ALLOW FOR EGRESS, WHEN BEDROOMS ARE
 LOCATED ON THE ZERO LOT LINE SIDE.
 5-SHEET C-1: REVISE FOUNDATION NOTES.
 MINIMUM VAPOR BARRIER TO BE 6 MIL, NOT
 4 MIL. SEC. 1909.2 FBC 2001.
 6-FOOTING FOR PRIVACY WALL AT ZERO LOT
 LINE WALL IS ENCROACHING INTO OTHERS
 PROPERTY. REVISE AS REQUIRED.
 7-GLASS BLOCK AT BATHROOM AREAS TO BE
 SAFETY GLASS IF FACE THICKNESS IS LESS
 THAN 0.25". SEC. 2405.2 FBC 2001.
 8-PROVIDE COMPLETE DETAIL AND FASTENER
 SPECIFICATIONS FOR INSTALLATION OF
 HANGING AIR HANDLING UNIT.SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 9-PROVIDE COMPLETE SPECS FOR GARAGE DOOR
 STRUCTURAL BUCK DETAIL. NEED COMPLETE
 SIZE OF ANCHOR AND WASHER.SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 10-UPDATE TRUSS ANCHOR SCHEDULE, DETAIL
 3/A5 AND ALL DETAILS THAT NEED TO
 REVISE THE LOADS TO COMPLY W/ SECTION
 1609.4.3 FBC 2001, WHICH DOES NOT
 ALLOW33% ALLOWABLE STRESS INCREASE
 TO BE USED.SEE USP 2003 CATALOGUE
 WHICH HAS THE REVISED VALUES.
 11-REVISE DETAIL 2/A5: NEED 2X BUCK TO
 SUPPORT WINDOW. SEE PRODUCT APPROVAL.
 SEC. 104.2.1.2. CITY AMENDMENTS TO FBC
 12-ENERGY CALCULATIONS: A)PROVIDE
 COMPLETE AND CORRECT INFORMATION ON
 TOP OF FORM. EG: ADDRESS AND OWNER
 INFORMATION.
 B)CONDITIONED FLOOR AREA DOESN'T MATCH
 AREA SHOWN ON ARCHITECT'S DRAWINGS.
 13-STORM SHUTTERS: REVISE MINIMUM AND
 MAXIMUM PANEL SPAN ON INSTALLATION
 SCHEDULE. SEE ENGINEERED DRAWINGS AND
 DESIGN PRESSURES CALCULATED ON PLANS.
 14-SEE ADDITIONAL COMMENTS ON REVIEWED
 SET OF PLANS. PLEASE RETURN REVIEWED
 SET AFTER CORRECTIONS ARE DONE TO THE
 ORIGINAL CAD DRAWINGS TO EXPEDITE THE
 REVIEW PROCESS.
 15-NEED TO UPDATE WORKER'S COMPENSATION
 INSURANCE.
 16-SEE COMMENTS BY PLUMBING.