| Date |
Text |
| 2003-05-19 00:00:00 | 1) BEFORE A PERMIT TO CONSTRUCT MAY BE |
| | ISSUED THE IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY, THE PERMIT PLANS |
| | STAMPED BY THAT OFFICE AND ACOPY OF |
| | THE PAID RECEIPTATTACHED TO THE |
| | PERMIT APPLICATION.CALL 561-233-5025 |
| | FOR MORE INFORMATION. |
| | |
| | 2) SHEET S1.1, NOTES #2.6 CALLS FOR |
| | "EARTHFORMS" WHICH IS NOT ALLOWED BY |
| | FBC1804.1.1 AS AMENDED BY THE CITY OF |
| | WEST PALM BEACH.PLEASE REVISE |
| | ACCORDINGLY. |
| | |
| | 3) THE SOUTHERN STRUCTURES METAL |
| | BUILDING PLAN DECLARES WIND DESIGN FOR |
| | 130 MPH. |
| | THE CITY OF WEST PALM BEACH IS IN AN |
| | 140 MPH ZONE. |
| | |
| | 4) SHOW THE WIND DESIGN INFORMATION IN |
| | ACCORDANCE WITH FBC 1606.1.7 ON THE |
| | STRUCTURAL PAGE. |
| | |
| | 5)SHEET CV-1 CITES 110 MPH FOR DOORS |
| | AND WINDOWS, SEE ABOVE. |
| | |
| | 6) THE AREA INCREASE ALLOWED BY FBC 503. |
| | 2 IS APPLIED TO THE UNSPRINKLERED AREA |
| | IN TABLE 500 NOT SPRINKLERED. (16000 IN |
| | THIS CASE.)IT IS STILL WITHIN THE AREA |
| | INCREASE BUT PLEASE CORRECT AS |
| | NECESSARY. |
| | |
| | 7) THE METAL BUILDING PLANS DO NOT |
| | INDICATE ANY SPECIAL CONDITIONS FOR THE |
| | ATTACHMENT OF THE EXTERIOR STUCCO |
| | SYSTEM IN SEVERAL PLACES.SEE FBC |
| | 2504.2 AND PROVIDE THE NECESSARY |
| | CONSTRUCTION DETAILS. |
| | |
| | 8)WILL THE MASONRY WALL BE |
| | TRANSFERRING LOADS OR FORCES TO THE |
| | METAL BUILDIN?PLEASE NOTE THE |
| | LOCATION, DIRECTION, NATURE AND |
| | MAGNITUDE OF THOSE FORCES ON THE PLANS. |
| | |
| | 9) WHAT IS THE NATURE AND |
| | CHARACTERISTICS OF THE COMMODITIES THAT |
| | ARE INTENDED TO BE STORED IN THIS |
| | BUILDING? |