| 2003-05-23 00:00:00 | *******CORRECTIONS******* |
| | |
| | SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)PROVIDE THE ORIGINAL RECEIPT FOR |
| | THE IMPACT FEES PAID TO PALM BEACH |
| | COUNTY. |
| | |
| | 2.)DOOR AND WINDOW BUCK DETAILS MUST |
| | COMPLY WITH FBC 1704.2.2. |
| | |
| | 3.)PROVIDE A DETAIL FOR THE PRIVACY |
| | WALL SHOWN ON THE SITE PLAN.ALSO |
| | SHOW ON THE FOUNDATION PLAN IF IT IS |
| | TO HAVE A FOOTER. |
| | |
| | 4.)THE SEMCO ATTACHMENT SPECIFIED IN |
| | THE WOOD FRAME TO CONCRETE WALL |
| | CONNECTION (A5) IS NOT AVAILABLE. |
| | PROVIDE ANCHOR LENGTH. |
| | |
| | 5.)THE TEXT, EXTERIOR WINDOW HEADER |
| | (S3) IS ILLEGIBLE. |
| | |
| | 6.)UPLIFT VALUES FOR CONNECTIONS ARE |
| | INCORRECT; REFER TO USP 2003 CATALOG. |
| | |
| | 7.)THE STAIR RAIL IS SHOWN AS 42" ON |
| | THE FLOOR PLAN AND NOTE 1 (A4), BUT IS |
| | 36" ON THE SECTION.EITHER COMPLIES, |
| | BUT MAKE ALL DETAILS AND DIMENSIONS |
| | MATCH. |
| | |
| | 8.)PROVIDE A SOILS INVESTIGATION |
| | REPORT. |
| | |
| | 9.)THE TEXT FOR "GUARDRAIL" AND THE |
| | DIMENSION ARE OVERLAYED; STAIR SECTION |
| | (A4); MAKE LEGIBLE. |
| | |
| | 10.)NOTES 6 & 7, EXTERIOR STUCCO (A4), |
| | RIB LATH IS TO BE ATTACHED AT EACH |
| | RIB, FBC 2504.2. |
| | |
| | 11.)DRAFTSTOPPING REQUIRED, FBC 705.3. |
| | |
| | 12.)PROVIDE PRODUCT APPROVALS FOR THE |
| | SLIDING GLASS DOOR. |
| | |
| | 13.)THE OVERHANG OF THE ROOF HAS |
| | SOFFIT VENTS ONTO THE ADJACENT PROPERTY |
| | (ZERO LOT LINE SIDE), AND THE ROOF |
| | DRAINS WATER ONTO THE ADJACENT PROPERTY. |
| | IS THIS COVERED IN AN EASEMENT? EITHER |
| | ADDRESS ON THE PLAN, OR PROVIDE A COPY |
| | OF THE EASEMENT. |