| Plan Review Notes For Permit 03041590 |
| Permit Number |
03041590 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-05-09 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | TO THE PLAN FOR CODE COMPLIANCE. | | | | | | 1} INDICATE THE LOCATION OF THE SERVICE | | | EQUIPMENT ON THE DRAWING. | | | | | | 2} PLEASE NOTE THAT THE GROUNDING | | | ELECTRODE CONDUCTOR MUST BE SIZED PER | | | 250-66 AND RAN CONTINUOUS PER 250-64(C). | | | | | | 3} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1. | | | | | | 4} THE OVEN LISTED FOR THE LOAD CALC | | | MUST COMPLY WITH 220-19 (8KW). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|