2003-05-09 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 TO THE PLAN FOR CODE COMPLIANCE.
  
 1} INDICATE THE LOCATION OF THE SERVICE
 EQUIPMENT ON THE DRAWING.
  
 2} PLEASE NOTE THAT THE GROUNDING
 ELECTRODE CONDUCTOR MUST BE SIZED PER
 250-66 AND RAN CONTINUOUS PER 250-64(C).
  
 3} PLEASE NOTE KITCHEN COUNTER-
 -SPACE RECEPT SPACING SHALL MEET ART;
 210-52C 1.
  
 4} THE OVEN LISTED FOR THE LOAD CALC
 MUST COMPLY WITH 220-19 (8KW).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  