2003-06-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 AMENDMENTS, CHAPTER
 1, ADMIN CODE
  
 1) SHT E2 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN NOR DOES IT
 MEET CODE REQUIREMENTS. THE RISER DIA-
 GRAM SHALL BE DRAWN AS IT WILL BE IN-
 STALLED. MASTER BATH SHALL BE UPSTREAM
 OF POWDER ROOM, BATH 2 SHALL BE UPSTREAM
 OF THE LAUNDRY ROOM. 104.2.1
 ALL TUB AND SHOWER TRAPS SHALL BE TAKEN
 OFF THE BRANCH LINES ON THE HORIZONTAL
 AS TO NOT BE AN "S" TRAP. BATH 2 TUB NOT
 VENTED. WASH MACHINE IS NOT VENTED AND
 REQUIRES A STANDPIPE. W/C AND SHOWER IN
 BATH 3 NOT VENTED. BBQ SINK SHALL NOT
 DRAIN INTO THE HORIZONTAL WET VENT OF
 THE CABANA BATH.
 SEE SECTIONS 909.1 - 1002.3(5) - 901.2.1
 802.4
 2) SEE ATTACHED SHEET CONCERNING FLORIDA
 STATUTE 553.80(2)(B)
 3) FLA STATUTE 61G1-16.003 THE PERSONAL
 SEAL, SIGNATURE, AND DATE ARE REQUIRED
 ON ALL DOCUMENTS TO BE FILED FOR PUBLIC
 RECORD PREPARED BY AN ARCHITECT. THE
 DATE IS MISSING FROM ALL SHEETS. ALSO
 ALL CHANGES TO A SIGNED AND SEALED SET
 OF DRAWINGS SHALL BE SIGNED AND DATED BY
 THE ARCHITECT OF RECORD.
  