| Plan Review Notes For Permit 03040916 |
| Permit Number |
03040916 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-05-06 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-RESUBMIT STORM SHUTTERS INFORMATION | | | WITH UPDATED SBCCI REPORT THAT MATCHES | | | ENGINEERED DRAWINGS. | | | 2-REVISE DETAIL S21 FOR COLUMN LOCATED | | | BETWEEN GARAGE AND STAIRWAY TO MATCH | | | CONDITIONS SHOWN ON 2ND. FL. FRAMING | | | PLAN. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO FBC 2001. | | | 3-ROOF FRAMING PLAN: REVISE CONNECTOR | | | TC-1 AT FRONT FRAMED WALL. NEED WOOD | | | TO WOOD CONNECTOR. SECTION 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | 4-WINDOW 34SH DOESN'T PROVIDE THE 24" | | | CLEAR HEIGHT REQUIRED BY SEC. 1005.4 | | | FBC 2001. REVISE AS REQUIRED. |
|