| Date |
Text |
| 2004-01-17 00:00:00 | *****CORRECTIONS****** |
| | |
| | REVISION #1 |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)FIREBLOCK REQUIRED, FBC703.1.3. |
| | |
| | 2.)SEPARATE PERMITS REQUIRED FOR |
| | ROOF, WINDOW, DOOR, IMPACT PROTECTION, |
| | GARAGE DOOR, EXTERIOR DOOR. |
| | |
| | 3.)TYPE IV CONSTRUCTION IS DECLARED |
| | ON AM-11; CLARIFY. |
| | |
| | 4.)THE PLANS ARE NOT SIGNED, SEALED |
| | AND DATED. |
| | |
| | 5.)ADDITIONAL FEES DUE (VALUE |
| | ADJUSTMENT AND RADON), $251.91 BZ235299. |
| | |
| | 6.)CONFIRM THE BUCK DETAIL ON THE |
| | PLAN WITH THE PRODUCT APPROVAL (NO |
| | PRODUCT APPROVALS SUBMITTED AT THIS |
| | TIME). (GARAGE DOOR) |
| | |
| | 7.)PROVIDE A WINDOW AND DOOR BUCK |
| | ATTACHMENT SCHEDULE. |
| | |
| | 8.)THE DESIGN UPLIFT FOR USP DTC |
| | (1-AMS-11) EXCEEDS MAX ALLOWED BY THE |
| | MANUFACTURER, SEE USP 2004 CATALOG. |
| | CHECK ALL CONNECTORS. |
| | |
| | 9.)SITE DEVELOPMENT DATA AS-1 SHOWS |
| | THE MAINTENANCE BUILDING AS 400SF; |
| | REVISE TO REFLECT THE NEW 620 TOTAL. |
| | |
| | 10.)BUILDING 9 MUST NOW COMPLY WITH |
| | TABLE 600 REQUIREMENTS FOR 10-20' |
| | SEPARATION.DECLARE A BUILDING |
| | CONSTRUCTION TYPE FOR BUILDING 9 ON THE |
| | PLAN AND SHOW COMPLIANCE. |
| | |
| | 11.)THE USE AND SIZE OF THE BUILDING |
| | HAS CHANGED.IMPACT FEES MAY BE DUE. |
| | 233-5025 |
| | |
| | 12.)LAUNDRY IS A BUSINESS OCCUPANCY |
| | FBC304.1.2.2 HR SEPARATION REQUIRED |
| | FBC TABLE 704.1. |