Plan Review Notes
Plan Review Notes For Permit 03040734
Permit Number 03040734
Review Stop B
Sequence Number 2
Notes
Date Text
2003-07-30 00:00:00******CORRECTIONS******
  
 1.)THE AREA CALCULATIONS STATE THAT
 THE ADDITIONAL LIVING SPACE IS 356
 SQUARE FEET, BUT THE IMPACT FEE STAMP
 AND THE ENERGY CALC IS FOR 264 SQUARE
 FEET.ALL THREE SHOULD BE CONSISTENT.
 PLEASE CLARIFY.
  
 2.)STUCCO OVER WIRE LATH IS REQUIRED
 TO BE 3 COAT (7/8"); FBC2504.2.2,
 ASTM C1063.
  
 3.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 4.)SEE PREVIOUS CORRECTION LIST, ITEM
 #2; IMPACT PROTECTION REQUIRED FOR
 GLAZING FBC10606.1.4.HOW WILL SHUTTERS
 BE INSTALLED IN THE METAL FRAME WALL?
 PROVIDE A DETAIL AND A HURRICANE SHUTTER
 ATTACHMENT SCHEDULE, SEE ATTACHED.
  
 5.)SEE THE PREVIOUS CORRECTION LIST,
 ITEM 3.THE WINDOW PRODUCT APPROVAL
 IS ACCEPTABLE BUT THERE WAS ONLY ONE
 COPY SUBMITTED.THE DOCUMENTATION
 SUBMITTED FOR THE SLIDING GLASS DOOR
 IS TO RENEW A PRODUCT APPROVAL.THE
 ACTUAL PRODUCT APPROVAL WAS NOT
 PROVIDED.PRODUCT APPROVALS FOR THE
 IMPACT PROTECTION WERE NOT SUBMITTED.
 CURRENT PRODUCT APPROVALS ARE AVAILABLE
 AT WWW.MIAMIDADE.GOV (FIND A DEPT, BLDG
 CODE COMPLIANCE, PRODUCT CONTROL, SEARCH
 APPROVED PRODUCTS).
  
 6.)PROVIDE WIND DESIGN INFORMATION,
 FBC1606.1.7.
  
 7.)THE SEAL MUST BE DATED FAC61G15-23.
 002(1).SEE ATTACHED.
  
 8.)IF THE ENGINEER MAKES CHANGES TO
 THE SEALED PLAN, HAVE THE CHANGES
 INITIALED AND DATED.
  
 9.)SUBMIT BOTH COPIES OF THE 1ST
 SUBMITTAL WITH THE APPROVED ELECTRIC
 DRAWING.IF BOTH ARE NOT SUBMITTED,
 THE PLANS WILL REQUIRE AN ELECTRIC
 REVIEW WITH THE NEXT RESUB.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]