| 2003-05-12 00:00:00 | BUILDING DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT THE RECEIPT FOR THE COUNTY | | | IMPACT FEES. | | | | | | 3) SUBMIT A SOIL BORING TEST REPORT AS | | | REQUIRED BY CITY AMENDMENTS TO THE FBC | | | 1804.2.2. | | | | | | 4) REVISE ITEM #7 UNDER STUCCO SPECS. ON | | | A-3 TO REQUIRE FASTENING AT EVERY RIB | | | (4"O.C.) AS REQUIRED BY ASTM C 1063. | | | ITEMS #4 AND #5 ARE THE SAME NOTE. | | | | | | 5) THE CONDITIONED AREA ON THE ENERGY | | | CALCULATIONS IS 2292 SQFT AND THE PLANS | | | LIST 2260 SQFT OF A/C SPACE. PLEASE | | | CORRECT. | | | | | | 6) REVISE THE TRUSS CONNECTOR UPLIFT | | | VALUES TO VALUES THAT DO NOT INCLUDE THE | | | STRESS INCREASE ON THE STEEL CALCS. | | | WHICH ARE NO LONGER ALLOWED BY THE FBC. | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR A SINGLE | | | OUTSWING DOOR WITH SIDELITE. | | | | | | 8) THE OWNER OF RECORD INDICATED ON THE | | | PERMIT APPLICATION IS INTELLI HOMES, | | | HOWEVER THE COUNTY PROPERTY APPRAISER | | | AND THE CITY RECORDS LIST TIDES PALM | | | BEACH LTD PARTENERSHIP AS THE OWNER. | | | PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|