Plan Review Notes
Plan Review Notes For Permit 03032207
Permit Number 03032207
Review Stop B
Sequence Number 1
Notes
Date Text
2003-04-21 00:00:00**********CORRECTIONS************
  
 1.)PROVIDE A FOOTPRINT OF THE HOUSE
 SHOWING WINDOWS TO BE REPLACED (NOT
 WINDOWS BEING REGLAZED).INDICATE
 BEDROOM WINDOWS, IF ANY.FBC 1004.5.
  
 2.)WINDOWS BEING REPLACED (NOT
 REGLAZED) ARE TO HAVE HURRICANE
 PROTECTION, FBC1606.1.4, FBC 3401.7.2.4.
  
 3.)SUBMIT 2 COPIES OF PRODUCT
 APPROVALS FOR THE FOLLOWING:
 WINDOWS (REPLACEMENT ONLY, NOT
 WINDOWS TO BE REGLAZED)
 HURRICANE SHUTTERS
 EXTERIOR DOORS BEING REPLACED
  
 4.)WHEN SUBMITTING PERMITTING
 PAPERWORK, PLEASE ALWAYS SUBMIT TWO
 COPIES.ONE COPY REMAINS IN OUR RECORDS
 AND ONE IS FOR YOUR PERMIT SET.ONLY
 ONE SEALED SET OF STRUCTURE INSPECTION
 RESULTS WAS SUBMITTED; 2ND COPY OF
 REPAIR DETAILS WAS NOT SEALED.
  
 5.)WHEN INDICATING AN ATTACHMENT,
 EITHER SPECIFY BRAND AND TYPE, OR GIVE
 UPLIFT REQUIREMENTS.DETAILS SHOULD
 INCLUDE TYPE OF LUMBER, SIZE, AND
 SPECIFIC ATTACHMENTS.
  
 6.)FOR CLARITY, LABEL THE VARIOUS
 ATTACHMENT DETAILS (A, B, C, ETC.) AND
 ON THE STRUCTURE INSPECTION RESULTS AND
 REPAIR DETAILS SHEET, REFER TO THE
 SPECIFIC DETAIL FOR THE VARIOUS ITEMS.
  
 7.)THE WALL FRAMING/WALL SHEATHING
 DETAIL SHEETS ARE NOT LEGIBLE.PLEASE
 SUPPLY LEGIBLE COPIES.ALSO IT REFERS
 TO AN ATTACHMENT SCHEDULE FOR THE BOTTOM
 PLATE WHICH IS NOT ON THE SHEET.THE
 NAILING SCHEDULE AT THE TOP OF THE PAGE
 CONFLICTS WITH THE NAILING IN THE TEXT
 OF THE DIAGRAM.
  
 8.)PROVIDE A TITLE BLOCK FOR ALL
 SEALED SHEETS.SEALS SHOULD BE DATED
 AS WELL AS SIGNED.
  
 9.)BEFORE A PERMIT CAN BE ISSUED,
 THE HOLDS ON THIS PROPERTY MUST BE
 ADDRESSED.SEE ATTACHED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]