| Date |
Text |
| 2003-04-22 00:00:00 | BUILDING DENIED |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) THE CBS WALL (FENCE) WILL REQUIRE A |
| | SEPARATE PERMIT. A UTILITY EASEMENT |
| | RELEASE IS REQUIRED BEFORE PERMIT CAN BE |
| | ISSUED. |
| | |
| | 3) THE GUTTER DOWN SPOUTS ARE REQUIRED |
| | TO DISCHARGE A MINIMUM OF ONE FOOT FROM |
| | THE STRUCTURE SIDEWALLS PER FBC 1503.4.4 |
| | |
| | 4) THE CONNECTORS SPECIFIED ARE |
| | MANUFACTURED BY HUGHES WHICH WAS |
| | PURCHASED BY USP SOMETIME AGO. PLEASE |
| | UPDATE CONNECTORS TO CURRENT USP OR |
| | SIMPSON PRODUCTS. |
| | |
| | 5) SPECIFY WASHERS FOR THE 5/8" J BOLTS |
| | ANCHORING THE 2X BASE PLATE TO THE STEM |
| | WALL. |
| | |
| | 6) THE PT BASE PLATE ON THE STEM WALL IS |
| | SPECIFIED AS A 2X8, BUT APPEARS TO BE A |
| | 2X6. PLEASE CLARIFY. |
| | |
| | 7) CLARIFY HOW THE 2X8 LEDGER WILL BE |
| | BOLTED TO THE EXTISTING STRUCTURE. WILL |
| | IT BE THROUGH BOLTED TO THE EXISTING |
| | FLOOR SILL? SPECIFY WASHER TYPE/SIZE. |
| | |
| | 8) THE WINDOWS ON THE ELEVATIONS ARE |
| | SHOWN AS SINGLE HUNG (EXCEPT AT KITCHEN |
| | AND DINING ROOM) AND PLANS ON A2 DO NOT |
| | INDICATE SH WINDOWS. PLEASE INDICATE |
| | WHICH WINDOWS ARE SINGLE HUNG, CASEMENT |
| | AND FIXED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |