| Plan Review Notes For Permit 03032080 |
| Permit Number |
03032080 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-04-30 00:00:00 | PLEASE NOTE WHICH MULLION THICKNESS AND | | | LENGTH WILL BE USED IN THE FAMILY ROOM | | | AND LIVING ROOM EXTERIOR DOOR AND FIXED | | | LIGHT SYSTEM. | | | | | | PAGE 8 OF 8 IS MISSING FROM THE 02-0701. | | | 07 NOA (PGT FIXED WINDOW) | | | | | | THE WAYNE DALTON SHEETS, (GARAGE DOORS) | | | ARE NOT NOTICE OF ACCEPTANCE OR TEST | | | REPORTS.FURTHER, THE DESIGN PRESSURES | | | ON THEM ARE LOWER THAN THOSE DECLARED | | | ON THE PERMIT PLANS. | | | | | | SAFETY GLASS IS REQUIRED AT THE EXTERIOR | | | WINDOW IN THE MASTER BATH BY THE | | | WHIRLPOOL TUB.FBC 2405.2.1 #2. | | | | | | PLEASE PROVIDE A COPY OF THE PAID | | | RECEIPT FROM PALM BEACH COUNTY FOR THE | | | IMPACT FEES. |
|