Plan Review Notes
Plan Review Notes For Permit 03032055
Permit Number 03032055
Review Stop B
Sequence Number 1
Notes
Date Text
2003-04-30 00:00:00 
  
 BUILDING PLAN REVIEW
 PERMIT: 03032055
 ADD: 10295 SAND CAY LANE
 CONT: G W PURUCKER HOMES
 TEL: (561)775-1170
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION : DENIED
  
 *************NOTE*************
 FUTURE POOL
 1803.1.3 EXCAVATION FOR ANY PURPOSE
 SHALL NOT EXTEND WITHIN 1 FT OF THE
 ANGLE OF REPOSE OR NARURAL SLOPE OF THE
 SOIL UNDER ANY FOOTING OR FOUNDATION,
 UNLESS SUCH FOOTING OR FOUNDATION IS
 FIRST PROPERLY UNDERPINNED OR PROTECTED
 AGAINST SETTLEMENT.
  
  
 1) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 2)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD.
  
 A) CASTLEGATE/ MASONITE DOOR SITE
 SPECIFIC ENGINEERING! CITY FORM ATTACHED
  
 3)STORM HUTTERS: HIGHLIGHT WHAT TYPE OF
 WALL ATTACHMENTS THAT ARE BEING USED TO
 ANCHOR THE STORM SHUTTERS, IN THE REPORT
 AS WELL AS THE TECHNICAL SHEETS.
  
 THE SECOND PROBLEM IS USING THE CONCRETE
 TABLES 12" VERSES THE MASONARY TABLES!!!
  
 INDICATE HOW EGRESS WILL BE MAINTAINED
 WITH STORM SHUTTERS ON FRONT DOORS.
  
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 4)TRUSSES:
 THE ENGINEERED TRUSS DRAWINGS & LAYOUT
 ARE NOT REQUIRED FOR PLAN REVIEWOF A
 SINGLE FAMILY HOUSE. THEY WILL BE
 REQUIRED AT TIME OF ROOF FRAMING INSPEC-
 TION. IF SUBMITTED THEY ARE TO BE
 REVIEWED FOR CODE COMPLIANCE!
  
 ANCHOR SCHEDULE:
 (TA22) USP LUGT C2 F1= 500
 (TA24) USP HC10 USP 2003 CATALOG
 USP ISSUED A PRODUCTS DELETED
 FROM THEIR 2003 CATALOG!
 SHEET A-5 (TA-13) USP TA20 R VALUE FOR
 ONE STRAP 1520 OK! 2003 CATOLOG
 TWO STRAPS ONLY GOOD FOR 2750
  
 THE ENGINEERED TRUSS INDEX SHEET, I'VE
 HIGHLIGHTED TRUSSES WITH PROBLEMS
  
 THE TRUSS PLACEMENT DIGRAM JOB # 10263
 INDICATES A TRUSS/TRUSS CONNECTORS
 I CAN NOT LOCATE EHUH26 IN EITHER USP OR
 SIMPSON.
  
 ON A-5.1 GIRDER GR-7 NO INFO ON PLANS
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026