2003-04-09 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03031179
 ADD: 4200 BEAR LAKES CT
 CONT: (PLAN REVIEW)
 IRA GROSSMAN
 TEL: (786)367-1537
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST $250.00 PLAN REVIEW
  
 NOTE: SUBMIT (3) SETS OF PLAN FOR THE
 PERMIT SET OF PLANS, RESIDENT INSPECTOR
 PROGRAM.
  
 A PERMIT APPLICATION SHALL BE REQUIRED
 TO BE FILLED OUT BY THE CONTRACTOR BE-
 FOR THE PERMIT MAY BE ISSUED.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 424.1PUBLIC SWIMMING POOLS: 64E-9.002
 PROVIDE ADDITIONAL INFORMATION ON THE
 EFFECTIVE BARRIER (FENCE) FOR THE POOL
 AND BETWEEN THE POOL AND CLUBHOUSE.
  
 3) FAIR HOUSING ACT, ACCESSIBLE ROUTE:
 A) MISSING ACCESS ISLES ACROSS STREETS
 B) MISSING SIDEWALK BEHIND PARKING
 NORTH OF DUMPSTER
 C) DUMPSTER STAIRS, NO RAMP INDICATED
  
 ACCESSIBLE ROUTES ALSO MAY INCLUDE SKY
 WALKS,TUNNELS,GARAGES, AND PARTS OF MANY
 PUBLIC AND COMMON AREAS. ANSI 4.3 CON-
 TAINS COMPLETE TECHNICAL SPECIFICATIONS
 FOR ACCESSIBLE ROUTES, INCLUDING, WIDTH,
 HEADROOM, SURFACE TEXTURE, SLOPE,
 CHANGES IN LEVEL, DOORS, AND EGRESS IN
 EMERGENCIES.
  
 4) FAIR HOUSING ACT 4.3 WALKING SURFACES
 403.2 FLOOR & GROUND SURFACES SHALL
 COMPLY WITH SECTION 302. SECTION 302.2
 DEALS WITH CARPET. FINISH ROOM SCHEDULE
 NO INFORMATION.
  
 5) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 PROVIDE SOILS REPORTS.
  
 6) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 7) FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
  
 (2) OFFICES, 2405.2.1(3) WINDOW (H)
 RACHUET BALL COURT, 2405.2.1(2) GLAZING
 LOCATED WITHIN 36" OF WALKING SURFACES.
 NO INFORMATION ON DOOR OR WINDOWS BY
 ANDERSON.
  
 8) DOOR SCHEDULE AM-5 FRONT DOOR NOTE 3,
 AM-9 FOR CONNECTION OF FRENCH DOORS,
 SIDELIGHTS & TRANSOM. DETAIL # 10, ENTRY
 DOOR HEAD DETAIL SEE STRUCTURAL DRAWINGS
 NO INFORMATION TO REFER TO?
  
 DETAIL #12 FOR FRONT ENTRY, VERTICAL
 FRAMING MEMBER( MULLION) EITHER PRODUCT
 TESTING REPORT OR SITE SPECIFIC ENGIN-
 EERING.
 PLANS INDICATE THE USE OF (4) WEDGE
 ANCHORS TOP/ BOTTOM PLATE, IN THE TOP
 PLATE FASTENING INTO A BEAM THERE WILL
 BE ONLY 1 1/2" EDGE DISTANCE, HOW MUCH
 OF A DERATING FACTOR WAS FIGURED?
 STRUCTURAL SHEET AMS-2 MISSING
 THIS BEAM?
  
 9)1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
  
 10) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 11) SHEET AMS-4 GIVEN ROOF HEIGHT OF
 15'-0", WRONG HIGHEST BEAM 20'-8" PLUS
 1/2 HEIGHT OF TRUSS2'-4"= 23'-0".
  
 12) FOUNDATION SCHEDULES INDICATES (2)
 WF24A FOOTINGS, ONE 12" DEEP, THE OTHER
 16" DEEP, WHY IS THERE THE SAME MARK FOR
 2 DIFFERENT FOUNDATIONS? 1804.1.3 COUNTY
 WIDE AMENDMENT 1804.1.3 REQUIRES ALL
 FOUNDATIONS TO BE 12" BELOW GRADE PLUS
 THE SLAB ON GRADE (3 1/2").
  
 13) SHEET AMS-3 INDICATES A 3/4" RECESS
 IN THE SLAB. COUNTY AMENDMENT 2111.1.9
 REQUIRES A 1 1/2" RECESS.
  
 14) 1503.4.4 PROTECTION AGAINST DECAY &
 0ERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 15)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 16)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A)WINDOWS; FIXED & CASEMENT
 B)DOORS; SOLID & GLAZED
 C)MULLIONS
 D)STORM SHUTTERS
 E)ROOFING ASSEMBLIES
  
 17)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD.
  
 18) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 19) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 20)1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND TEST-
 ED FOR A PERIOD EQUAL TO THE QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
 PRESSURE. DADE COUNTY & SBCCI REPORTS
 ARE ACCEPTED.
  
 21)PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 22)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 23) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 24) ROOF TRUSS/ GIRDER SYSTEM:
 1606.2.4 MAIN WIND FORCE RESISTING SYS-
 TEM: ALL ELEMENTS AND CONNECTIONS OF THE
 MWFRS SHALL BE DESIGNED FOR VERTICAL AND
 HORIZONTAL LOADS BASED ON THE COMBINED
 LEEWARD AND WINDWARD WALL / ROOF PRES-
 URES.
 PROVIDE THE LOADING FOR TRUSSES AND
 GIRDERS MISSING ON SHEET AM-6.
  
 25)1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.
  
 26) TRUSS PLAN INDICATES "SEMCO" BOUGHT
 OUT IN 1999 BY USP USE 2003 USP CATOLOG
 AND PRODUCT NUMBERS.**** NOTE DECREASE
 IN VALUE FOR TRUSS ANCHORS THAT CAN BE
 TAKEN***1609.4.3 LOAD REDUCTIONS****
  
 27)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026