| 2003-04-12 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FHA-98 DESIGN MANUAL |
| | |
| | 1) COMMENTS FROM PREVIOUS REVIEW NOT |
| | ADDRESSED |
| | |
| | A) SHT A3.02 OPTIONAL BATHROOMS UNITS |
| | B & B(REV), W/C SHALL BE 18" OFF WALL |
| | AND NOT THE SHOWER. TOILETS POSITIONED |
| | BESIDE A WALL OFFER THE HIGHEST DEGREE |
| | OF SAFE USE SINCE A GRAB BAR CAN BE |
| | MOUNDET TO THE SIDE OF THE TOILET. P-6.5 |
| | (THIS IS ALSO THE CASE FOR UNITS IN THE |
| | FLOOR PLAN) |
| | B) SHT A3.03 THE CLEAR FLOOR SPACE DIME- |
| | NTIONS ARE TO BE APPLIED OR SUPERIMPOSED |
| | OVER A PLAN DURING THE DESIGN PROCESS TO |
| | DETERMINE IF SPACE REQUIREMENTS AT THE |
| | TOILETS ARE BEING MET. P-7.43 - THIS IS |
| | NOT SHOWN ON "C" OR "C"(REV) UNITS. |
| | *********WHEN RESUBMITTING PLANS******** |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |