| 2003-03-31 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03022362 |
| | ADD: 334 HUNTER ST |
| | CONT: O/B ANDERSON GEORGE |
| | TEL: (561)585-1301 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) SHEET 3.1 GENERAL NOTES (1) PLANS |
| | INDICATE THAT THE WORK SHALL COMPLY WITH |
| | THE STANDAERD BUILDING CODE. WE ARE |
| | CURRENTLY USING THE 2001 FLORIDA BUILD- |
| | ING CODE. |
| | |
| | 2) NOTE 12 INDICATES THE USE OF DEAD |
| | BOLTS FOR EXTERIOR DOORS. 1012.7 DOUBLE |
| | CYLINDER DEAD BOLTS ARE PROHIBITED ON |
| | REQUIRED MEANS OF EGRESS DOORS. |
| | |
| | 3) MISSING PRODUCT TESTING REPORTS FOR |
| | THE EXTERIOR DOORS 001 & 003. THE CITY |
| | ACCEPTS S.B.C.C.I. REPORTS OR DADE |
| | COUNTY PRODUCT ACCEPTANCE REPORTS. |
| | |
| | 4) SHEET 4.1 INDICATES THE BEAM 8"X22" |
| | BEING CUT DOWN TO 8"X12". WHEN CUTTING |
| | THE BEAM IN HALF WHAT STEEL WILL REPLACE |
| | THE BOTTOM TENSION STEEL? |
| | |
| | 5) SHEET 3.1 INDICATES A NEW (3) 2X12 |
| | WOOD BEAM TO SIT ON THE EXISTING TIE |
| | BEAM (EXTERIOR WALL). SHEET 4.1 DETAIL |
| | (3) INDICATES THAT IT SITS ON TOP OF THE |
| | TIE BEAM. HOW DOES THE DROP CEILING AT |
| | 7'-6" ATTACH TO THIS NEW BEAM? SEE |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)659-8096 X 8412 |
| | FAX: (561)659-8026 |