Plan Review Notes
Plan Review Notes For Permit 03022335
Permit Number 03022335
Review Stop E
Sequence Number 2
Notes
Date Text
2003-05-05 00:00:00************PROVISO/REVISE ************
  
 PLANS STILL MISSING THE FOLLOWING AND
 NEED TO BE REVISED BEFORE FINAL.
  
 1)NOTE: PLEASE SHOW SD`S INSIDE AND
 OUTSIDE BEDROOM. NFPA-72 8-1.4.2
  
 2)NOTE: PLEASE SHOW EQUIPMENT GROUNDING
 CONDUCTOR BETWEEN MAIN DISC AND PANEL.
 250-24/250-122
  
 3)NOTE: PLEASE SHOW ALL KITCHEN COUNTER-
 -SPACE RECEPTS AS GFI/GFI PROTECTED.
 210-8-A-6
  
 4)NOTE: PLEASE SEE MISSING REAR RECEPT
 PER 210-52E.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE FINAL. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  