Plan Review Notes
Plan Review Notes For Permit 03021865
Permit Number 03021865
Review Stop B
Sequence Number 1
Notes
Date Text
2003-03-31 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE ENERGY CALCULATIONS AS
 AS REQUIRED BY CHAPTER 13 OF THE FBC.
  
 4) PROVIDE TWO COPIES OF A RECENT
 SURVEY.
  
 5) LARGE MISSILE IMPACT PROTECTION IS
 REQUIRED FOR ALL NEW GLAZED OPENINGS.
 PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
  
 6) THE WALL SECTION ON A2 SPECIFIES R-19
 BLOWN INSULATION. THIS WILL NOT BE
 POSSIBLE WITH A SINGLE ASSEMBLY ROOF/
 CEILING SYSTEM AS SHOWN.
  
 7) THE SIMPSON TS-18 SPECIFIED ON A2 IS
 A WOOD TO WOOD CONNECTOR. PLEASE REVISE
 TO A WOOD TO MASONRY CONNECTOR SUCH AS A
 MTSM 20. SPECIFY THE FASTENERS AS LISTED
 IN THE 2003 CATALOG.
  
 8) THE PLANS LIST 3636SH WINDOWS. PLEASE
 CLARIFY. ARE THESE H36 SINGLE HUNG
 WINDOWS AS THEY APPEAR TO BE ON THE
 ELEVATIONS? PROVIDE PRODUCT APPROVAL FOR
 THE WINDOWS AS SHOWN ON PLANS THAT WILL
 BE INSTALLED.
  
 9) SPECIFY ON THE DRAWINGS WEATHER THE
 DOOR AT THE REAR OF THE EXISTING
 STRUCTURE IS EXISTING OR NOT. IF IT IS
 NEW PROVIDE PRODUCT APPROVALS.
  
 10) THE NEW ADDITION CAN NOT BLOCK ANY
 EXISTING BED ROOM EGRESS WINDOWS OR BATH
 ROOM WINDOWS (UNLESS MECHANICAL VENT IS
 INSTALLED). IDENTIFY ON PLANS THE EXIST-
 ING ROOMS ADJACENT TO THE ADDITION.
  
 11)THE WIRE MESH IN THE SLAB IS REQUIRED
 TO BE SUPPORTED ON APPROVED MATERIALS AT
 MAX. OF 3 FEET O.C. PER FBC 1909.3.
 INDICATE ON THE PLANS.
  
 12) THE NEGATIVE WINDLOAD PRESSURES ARE
 INDICATED ON THE PLANS WITH POSITIVE
 SIGNS. PLEASE PLACE NEGATIVE SIGNS IN
 FRONT OF THE NEGATIVE PRESSURES ON A2.
  
 13) INDICATE ON THE WALL SECTION THAT
 THE FOOTING IS REQUIRED TO BE A MINIMUM
 OF 12" BELOW GRADE AND THE FINISH FLOOR
 ELEVATION IS REQUIRED TO BE A MINIMUM OF
 4" ABOVE FINISH GRADE. FBC 1804.1.3 AND
 CITY AMENDMENTS TO FBC 1804.1.7
  
 14) THE PLANS ARE REQUIRED TO HAVE A
 TITLE BLOCK WITH THE ENGINEER'S NAME,
 ADDRESS AND NUMBER. 61G15-23.002
  
 15) ADDITIONAL PERMITS WILL BE REQUIRED
 FOR ROOFING AND OTHER TRADES WITH
 ADDITIONAL FEES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202