| Plan Review Notes For Permit 03021580 |
| Permit Number |
03021580 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-04-30 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)BAY WINDOW DETAIL DOES NOT SHOW | | | ATTACHMENTS.THERE IS A CONFLICT | | | BETWEEN THE ROOF FRAMING PLAN (SHOWS | | | FLAT ROOF) AND THE WALL SECTION (SHOWS | | | PITCHED TRUSSES) AND ELEVATION (SHOWS | | | FLAT ROOF) FOR THE BAY WINDOW. | | | | | | 2.)A 52" HIGH SINGLE HUNG WINDOW DOES | | | NOT MEET EMERGENCY EGRESS REQUIREMENTS. | | | PLEASE ADDRESS. | | | | | | 3.)PROVIDE PRODUCT APPROVALS FOR | | | THE WINDOW MULLIONS FOR WINDOW #8. | | | | | | 4.)REFER TO COMMENT #35, POOL IS TO | | | COMPLY WITH FBC 424.2.17.1.NOT | | | ADDRESSED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|