| Plan Review Notes For Permit 03021564 |
| Permit Number |
03021564 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-07-15 00:00:00 | RE:SHOP DRAWINGS FOR RAMP GUARDRAIL | | | | | | 1.)THE PLAN SHOWS A LANDING OF 5'. | | | GUARDRAIL ONE DOES NOT SHOW THIS | | | LANDING.CLEARLY SHOW ON THE SHOP | | | DRAWINGS OF THE GUARDRAIL THE MIN. 60" | | | REQUIRED FOR LANDINGS FBC11-4.8.4. | | | | | | 2.)THE ORIGINAL PLAN SHOWS A 1'6" | | | EXTENSION OF THE GUARDRAIL (ONE) AT THE | | | TOP AND BOTTOM OF THE GUARDRAIL.THE | | | SHOP DRAWINGS HAVE REDUCED THIS TO | | | 1'4" AND 1'5 1/2".A MINIMUM OF 18" | | | IS REQUIRED FBC11-4.8.5(2). | | | | | | 3.)THE DIMENSION FOR HANDICAP RAMP | | | TWO WAS REVISED TO BE 34" (FROM 32"), | | | BUT THE DIMENSIONS ON THE OPPOSITE SIDE | | | OF THE DETAIL (20" AND 1') WERE NOT | | | CHANGED. | | | | | | 4.)THE ORIGINAL PLAN BY LCA | | | ARCHITECTURE, INC. STAES ON SHEET A3: | | | "RAIL NOTE: CONTRACTOR SHALL PROVIDE | | | RAIL ENGINEERING & SHOP DRAWINGS FOR | | | APPROVAL."HAVE THE ARCHITECT REVIEW | | | THE SHOP DRAWINGS. | | | | | | 5.)THE RAIL IS TO COMPLY WITH FBC | | | 1608.2. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|