| Plan Review Notes For Permit 03021008 |
| Permit Number |
03021008 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-04-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT A6 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS OR REFLECT | | | THE FLOOR PLAN. | | | 2) LAUNDRY TRAY AND WASH MACHINE CAN NOT | | | DRAIN INTO THE SAME STACK AS BATH #2 LAV | | | THEY ARE NOT ON A COMMON WALL. | | | 3) WASH MACHINE SHALL DRAIN DOWNSTREAM | | | FROM THE LAUNDRY TRAY NOT ABOVE. A CLEAN | | | OUT IS REQUIRED ON THE LAUNDRY STACK MIN | | | OF 4' AFF. | | | 4) TUBS IN MASTER BATH AND BATH #2 SHALL | | | NOT BE TAKEN OFF ABOVE THE SLAB AS SHOWN | | | 5) SHOWERS IN MASTER BATH, BATH #3, AND | | | CABANA BATH SHALL NOT BE TAKEN OFF ABOVE | | | THE SLAB AS SHOWN. | | | 6) BIDET IN MASTER BATH SHALL NOT BE | | | TAKEN OFF ABOVE THE SLAB AS SHOWN. | | | 7) SIZE ALL SECTIONS OF PIPE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|