| Plan Review Notes For Permit 03020961 |
| Permit Number |
03020961 |
|
| Review Stop |
B1 |
| Sequence Number |
33 |
|
| Notes |
| Date |
Text |
| 2004-09-21 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED 8/23/04 FOR DOORS | | | L1-23A THROUGH L1-27A LOUVERED DOOR | | | PRODUCT APPROVALS. | | | | | | 1) THE PRODUCT APPROVAL WAS BROUGHT IN | | | AS A SUBMITTAL.IT IS A REVISION AND | | | THE APPROPRIATE FEE IS $60. | | | | | | 2) DESIGN WIND PRESSURES.DRAWING SHEET | | | 1 OF THE SUBMITTED INGERSOLL-RAND | | | LOUVERED DOOR PRODUCT APPROVAL NOA# | | | 03-0327.02 STATES THAT THE DESIGN | | | PRESSURE RATING IS +60 PSF / -60 PSF. | | | THE PEAK POSITIVE AND NEGATIVE PRESSURES | | | FROM STRUCTURAL PLAN SHEETS S-22 AND | | | S-23 ARE +70 PSF AND -70 PSF.SUBMIT | | | A PRODUCT APPROVAL FOR DOORS WITH A | | | DESIGN PRESSURE RATING THAT EXCEEDS THE | | | PEAK POSITIVE AND NEGATIVE PRESSURES. |
|