| 2003-05-13 00:00:00 | ******CORRECTIONS******* |
| | |
| | 1.)FOUR SHEETS OF 2B WERE SUBMITTED; |
| | TWO ARE UNSEALED.UNSURE AS TO WHY TWO |
| | EXTRA COPIES WERE SUBMITTED BUT THEY |
| | NEED TO BE SIGNED AND SEALED IF THEY ARE |
| | TO BE A PART OF THE PERMIT PACKAGE. |
| | |
| | 2.)PROVIDE A LICENSE NUMBER FOR THE |
| | ARCHITECT; HAVE HIM SIGN,SEAL & DATE THE |
| | PLAN AS HIS TITLE BLOCK IS ON THE PLAN. |
| | |
| | 3.)SEPARATE PERMITS REQUIRED;ELECTRIC, |
| | PLUMBING, MECHANICAL, ROOFING. |
| | |
| | 4.)A NOTICE OF COMMENCEMENT IS |
| | REQUIRED TO BE FILED WITH THE CLERK OF |
| | COURTS BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 5.)SEE PREVIOUS CORRECTION NOTICE, |
| | ITEM #1.SUBMIT PRODUCT APPROVALS FOR |
| | THE MULLIONS, GARAGE DOOR, AND 3'0X6'8 |
| | DOOR. |
| | |
| | 6.)IF YOU MAKE CHANGES TO A SEALED |
| | DRAWING IN INK, THE CHANGES MUST BE |
| | INITIALED BY WHOEVER SEALS THE PLAN. |
| | |
| | 7.)FBC 1606.1.7, INFORMATION REQUIRED |
| | TO BE ON DRAWINGS. |
| | |
| | 8.)CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC, 2111.1.9 'WHERE EXTERIOR |
| | WALL MASONRY UNITS BEAR ON A CONCRETE |
| | FLOOR SURFACE, A 1.5 INCH RECESS SHALL |
| | BE PROVIDED TO MINIMIZE WATER INTRUSION |
| | INTO FINISHED AREA.' |
| | |
| | 9.)ENERGY CALCS REQUIRED FBC13-101.2. |
| | |
| | 10.)FBC 2307.1.1, SILL ANCHORAGE TO |
| | HAVE A MINIMUM EMBEDMENT OF 7". |
| | |
| | 11.)FIRESTOP REQUIRED FBC 705.3. |
| | |
| | 12.)PROVIDE NUMBER OF SOFFIT VENTS |
| | REQUIRED WITH SIZES. |
| | |
| | 13.)ATTIC ACCESS REQUIRED FBC 2309. |
| | |
| | 14.)AREA CALCULATIONS SHOULD SHOW A |
| | TOTAL OF LIVING SPACE, AND A TOTAL OF |
| | NON-A/C SPACE, NOT SHOW CALCS BY FLOOR. |
| | |
| | 15.)PROVIDE ROOF SHEATHING ATTACHMENT |
| | SCHEDULE, CITY OF WPB AMENDMENTS TO |
| | THE FBC, TABLE 2306.1. |
| | |
| | 16.)FBC 1403.1.6, 6" CLEARANCE FROM |
| | EXTERIOR WALL COVERING TO EARTH. |
| | |
| | 17.)PROVIDE ATTACHMENT UPLIFT |
| | INFORMATION. |
| | |
| | 18.)THE SITE PLAN SHOWS A NEW |
| | DRIVEWAY, SLAB ON THE NORTH SIDE OF THE |
| | PROPERTY, AND ADDITIONS TO THE FRONT |
| | AND REAR OF THE EXISTING HOUSE.REVISE |
| | TO REFLECT THE WORK TO BE PERFORMED |
| | UNDER THIS PERMIT.THE TRUSS PLANS |
| | SHOW WORK FOR THE ADDITION TO THE |
| | EXISTING HOUSE. |
| | |
| | 19.)THE PREVIOUS CORRECTION LIST #3, |
| | SUBMIT DETAILED DRAWINGS OF THE STAIRS, |
| | WAS NOT ADDRESSED. ONLY DRAWINGS FOR THE |
| | LANDING WERE GIVEN.STAIRS AND HANDRAIL |
| | TO COMPLY WITH FBC 1007. |
| | |
| | 20.)REFERENCE THE LANDING DETAIL; |
| | IN REGARDS TO THE POST TO BE |
| | EMBEDDED 2' INTO THE GROUND, IS THAT |
| | FOR THE SHORT POST AT THE BASE OF THE |
| | STAIRS, OR THE TALL POST GOING TO THE |
| | TOP OF THE STAIRS, OR BOTH?WILL THERE |
| | BE ANYTHING STABILIZING THE POSTS IN |
| | THE GROUND (STEEL THROUGH THE BASE, |
| | CONCRETE)? |
| | |
| | 21.)ANY CHANGES TO THE PLAN MUST GET |
| | HISTORIC APPROVAL.CHANGES WERE DRAWN |
| | IN FOR WINDOW SIZE AND CHANGING SINGLE |
| | WINDOWS TO DOUBLE.AFTER MAKING THE |
| | CHANGES TO THE PLAN, CLOUDED, TAKE BACK |
| | TO HISTORIC TO BE STAMPED. |
| | |
| | WHEN RESUBMITTING, PLEASE ASSEMBLE TWO |
| | COMPLETE PLAN SETS, IN ORDER.OLD |
| | SHEETS ARE TO BE BOUND SEPARATELY. |
| | MAKE A NOTATION ON THIS LIST AS TO HOW |
| | EACH ITEM HAS BEEN ADDRESSED IN ORDER |
| | TO EXPEDITE PLAN REVIEW.CLOUD CHANGES |
| | MADE TO THE PLAN. |
| | |