2003-02-26 00:00:00THE ALBERT A. GARGIULO, PE PLAN S1
 DATED2/17/03 DOES NOT HAVE SUFFICIENT
 FOUNDATION INFORMATION.
  
 SECTION 1 CALLS FOR A 3000# CAPACITY
 TIEDOWN.NOTE 1 CALLS FOR 6200# MIN
 ULTIMATE.
  
 THE SCHEDULE SHOWS THREE PIER TYPES.
 NONE ARE SELECTED.THE PLANS DO NOT
 SHOW THE LOCATION, PLACEMENT, TYPE OR
 NUMBER OF PIERS TO BE USED.
  
 THE SCHEDULE SHOWS TWO SOIL BEARING
 VALUES AS A FUNCTION OF VERTICAL TIES
 TO BE INCORPORATED.NO SELECTION IS
 SHOWN.
  
 THE FOUNDATION ENGINEER SHOULD REVIEW
 THE NOTE UNDER "FOUNDATION" ON SHEET OF
 1 OF 3 OF THE IMS PLAN DATED 11/12/02
 AND CHAPTER 61G15-31 RESPONSIBILTY
 RULES FO PROFESSIONAL ENGINEER
 CONCERNING THE DESIGN OF STRUCTURES, OF
 THE FLORIDA ADMINISTRATIVE CODE.
  
 THE FOUNDATION NOTES ARE NOT VERY
 LEGIBLE.