| Plan Review Notes For Permit 03011384 |
| Permit Number |
03011384 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-02-26 00:00:00 | THE ALBERT A. GARGIULO, PE PLAN S1 | | | DATED2/17/03 DOES NOT HAVE SUFFICIENT | | | FOUNDATION INFORMATION. | | | | | | SECTION 1 CALLS FOR A 3000# CAPACITY | | | TIEDOWN.NOTE 1 CALLS FOR 6200# MIN | | | ULTIMATE. | | | | | | THE SCHEDULE SHOWS THREE PIER TYPES. | | | NONE ARE SELECTED.THE PLANS DO NOT | | | SHOW THE LOCATION, PLACEMENT, TYPE OR | | | NUMBER OF PIERS TO BE USED. | | | | | | THE SCHEDULE SHOWS TWO SOIL BEARING | | | VALUES AS A FUNCTION OF VERTICAL TIES | | | TO BE INCORPORATED.NO SELECTION IS | | | SHOWN. | | | | | | THE FOUNDATION ENGINEER SHOULD REVIEW | | | THE NOTE UNDER "FOUNDATION" ON SHEET OF | | | 1 OF 3 OF THE IMS PLAN DATED 11/12/02 | | | AND CHAPTER 61G15-31 RESPONSIBILTY | | | RULES FO PROFESSIONAL ENGINEER | | | CONCERNING THE DESIGN OF STRUCTURES, OF | | | THE FLORIDA ADMINISTRATIVE CODE. | | | | | | THE FOUNDATION NOTES ARE NOT VERY | | | LEGIBLE. |
|