| Date |
Text |
| 2003-04-11 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 FUEL GAS |
| | FBC-2001 CHAPTER 11 |
| | |
| | 1) SHT A3 CALCULATIONS FOR ROOF #2 ALSO |
| | REQUIRED. CALCULATIONS SHALL BE ON PLANS |
| | INDICATE SLOPE OF GUTTER TO DOWNSPOUT |
| | PER TABLE 1106.6 |
| | 2) ALL NEW TOILET/BATHING ROOMS SHALL |
| | COMPLY WITH 11-4.22/11-4.23. ROOM 127 |
| | SHALL BE ACCESSIBLE BY CODE. |
| | 3) SHT A4 DOOR SHALL NOT OPEN INTO CLEAR |
| | FLOOR SPACE. 11-4.23.2. ROOM 127 STILL |
| | HAS DOOR OPENING INTO CLEAR FLOOR SPACE. |
| | 4) SHT A4 SHOWER STALLS SHALL COMPLY |
| | WITH 11-4.21.5 & 11-4.21.7. THESE DE- |
| | TAILS ARE NOT ON PLANS PER RESPONSE. |
| | 5) SUBMIT MANUFACTURE SHEETS FOR ALL GAS |
| | EQUIPMENT TO VERIFY COMPLIANCE WITH |
| | STANDARDS NFPA 54, AND THE FBC-2001 |
| | FUEL GAS CODE SECTION 402.2. |
| | NO RESPONSE. |
| | 6) SHTS A2 & A4 ROOM #127 ROOM SIZE |
| | SHALL BE MINIMUM OF 5'3" INSIDE FINISHED |
| | PLEASE SHOW DIMENSION. |
| | 7) SHT A4 DETAILS #3 & #7 GRAB BARS CAN- |
| | NOT EXTEND OVER LAV. SEE FIG. 29. |
| | RESPONSE SAYS REVISED BUT NO REVISION |
| | SHOWN. |
| | 8) SHT A4 ROOM 129 DOOR TO OUTSIDE. RE- |
| | SPONSE SAYS THAT PLAN WAS REVISED, BUT |
| | NO REVISION SHOWN |
| | 9) SHT A2 FUEL-FIRED WATER HEATERS SHALL |
| | NOT BE INSTALLED IN A BATHROOM OR A |
| | CLOSET ACCESSED THROUGH A BATHROOM. |
| | 10) THIS IS THE THIRD SUBMITTAL - A FEE |
| | IS DUE FOR RESUBMITTAL. $194.25 |
| | 11) THIS IS THE THIRD REVIEW. PLEASE BE |
| | AWARE OF FS 553.80(2)(B). SEE ATTACHED |
| | COPY. |
| | *********WHEN RESUBMITTING PLANS******** |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 659-8096 EXT 8377 |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |