 BUILDING PLAN REVIEW
 PERMIT: 03011187
 ADD: 700 S ROSEMARY # 113
 ARCH: HVC ARCHITECTS ( MICHAEL)
 TEL: (305)567-0602
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) 11-4.23.3 CLEAR FLOOR SPACE. A UNOBST
 RUCTEDTURNING SPACE COMPLYING WITH
 11-4.2.3 SHALL PROVIDED WITHIN AN ACCESS
 IBLE BATHROOM.
  
 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".