2003-03-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03010851
 ADD: 4500 S DIXIE HWY
 CONT: TUSCANI
 TEL: (561)586-3808
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) 11-4.1.2 VERTICAL ACCESSIBILITY,
 NOTHING IN THIS CODE SHALL BE CONSTRUED
 TO RELIEVE THE OWNER OF ANY BUILDING,
 SSTRUCTURE OR FACILITY FROM THE DUTY TO
 PROVIDE VERTICAL ACCESSIBILITY TO ALL
 LEVELS ABOVE OR BELOW THE OCCUPIAABLE
 GRADE LEVEL.
 11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENTRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
 11-4.1.6 ACCESSIBLE BUILDINGS:
 ALTERATIONS 1(B) IF EXISTING ELEMENTS,
 SPACES OR COMMON AREAS ARE ALTERED, THEN
 SUCH ALTERED ELEMENTS, SPACES, FEATURES,
 OR AREA SHALL COMPLY WITH THE APPLICABLE
 PROVISIONS OF 11-4.1.1 TO 11-4.1.3
 MINIMUM REQUIREMENTS FOR NEW CONSTRUC-
 TION.
  
 ADDITIONAL INFORMATION SHALL BE RE-
 QUIRED FOR THE USE OF THE VERTICAL
 PLATFORM LIFT.THE FOLLOWING WILL BE
 REQUIRED:
 (A) A NOTIRIZED LETTER FROM THE SCHOOL
 ADMINISTRATOR ATESTING THAT THE VER-
 TICAL LIFT WILL BE AVAILABLE FOR ANY
 ONE THAT MAY REQUIRE ASSISTANCE ONTO
 THE STAGE. THAT IT WILL BE READILLY
 AVAILABLE ON REQUEST.
 (B) LOCATE ON THE ARCHITECTS FLOOR PLAN
 THE LOCATION WHERE THE LIFT WILL BE
 USED AND INDICATE THE AREA IT WILL
 BE STORED AT WHEN NOT IN USE.
 (C) PROVIDE ADDITIONAL INFORMATION
 THE MANUFACTURES SPECIFICATIONS,
 WHAT TYPE OF DESIGN:ENTER/ EXIT OF
 LIFT, SYSTEMS DESCRIPTION OF PLAT-
 FORM, GUARDRAILS OR PANELS, DOORS
 OR GATES, DRIVE UNIT, CONTROLS,
 SIGNALS OR LIMIT SWITCHES, POWER
 REQUIRED, INDICATE ON THE FLOOR PLAN
 THE POWER SOURCE.
 (D) PROVIDE SHOP DRAWINGS OF THE SYSTEM
 WITH THE LOAD LIMITATIONS. IS THE
 SAFE LOAD NOT TO EXCEED INDICATED
 ON THE UNIT.
 (E) ASSUMING THIS IS A PORTABLE UNIT HOW
 IS THE TRANSITION FROM FINISH FLOOR
 TO THE VERTICAL LIFT MADE, WHAT IS
 THE SLOPE AND THE LENGTH OF THE RE-
 REQUIRED RAMP? HOW IS A SAFE TRANSI-
 TION MADE FROM THE VERTICAL LIFT
 WHILE IN USE TO THE STAGE?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412