2003-01-21 00:00:00BUILDING REVIEW COMMENTS:
 1-REVISE ENERGY CALCULATIONS:
 A)SEE PLANS FOR NUMBER OF BEDROOMS.
 B)COMPLETE TOP OF FORM. EG: ADDRESS,
 OWNER'S NAME, ETC. SEE FORM.
 C)OWNER/AGENT SIGN & DATE BOTTOM OF FORM
  
 2-34SH WINDOWS DON'T PROVIDE 24' CLEAR
 HEIGHT OPENING REQ'D BY SEC. 1005.4.4
 FBC 2001. CLARIFY/REVISE AS REQUIRED.
 ARE THESE CUSTOM MADE WINDOWS?
 3-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC. 2405.2.2 FBC 2001.
 4-PROVIDE SOIL TEST REPORT.
 5-PROVIDE DETAIL/SPECIFICATIONS FOR
 INSTALLATION OF CEILING AT FRONT AND
 REAR PORCH AS REQUIRED BY ASTM C926
 AND ASTM C-1063.(SEC. 2504.2 FBC 2001)
 6-SPECIFY SIZE OF ATTIC VENT. SECTION
 2309.6 FBC 2001.
 7-TYPICAL WALL SECTION. SPECIFY FIREBLOC
 KING. SEC. 2305.1.4 FBC 2001.
 **PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES
 AS REQUIRED BY SEC. 2305.1.4 FBC 2001.
 8-SPECIFY SUPPORTS FOR WWM IN CONCRETE
 SLAB. SEE SEC. 1909.3 FBC 2001.
 9-ADDRESS IS INCORRECT IN THE NOTICE OF
 COMMENCEMENT. REVISE STREET AS REQ'D.
 10-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS:
 A)PROVIDE KEY PLAN.
 B)PROVIDE INSTALLATION SCHEDULE. SEE
 ATTACHED CITY SAMPLE.
 C)CLEARLY MARK ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
  
 11-PROVIDE PRODUCT APPROVAL FOR GARAGE
 DOORS WITH LEGIBLE DRAWINGS.
 12-PRODUCT APPROVAL FOR ARCHED WINDOWS:
 A)NEED LEGIBLE DRAWINGS.
 B)MISSING PAGE 2 OF THE REPORT.
 C)CHECK DESIGN PRESSURES CALCULATED BY
 THE ENGINEER OF RECORD.
 13-RECTANGULAR WINDOW PRODUCT APPROVAL:
 A)NEED LEGIBLE DRAWINGS.
 B)PROVIDE PRODUCT APPROVAL FOR WINDOW
 SIZES AS SHOWN ON PLANS.
 C)PROVIDE STRUCTURAL BUCK DETAIL USING
 A 2X BUCK AS REQ'D ON THIS APPROVAL.
 14-PROVIDE COMPLETE PRODUCT APPROVAL
 REPORT AND DRAWINGS FOR CEMENT TILE.
 15-PROVIDE SBCCI OR DADE COUNTY PRODUCT
 APPROVAL FOR ENTRY DOORS, AND EXTERIOR
 SWING DOORS AS SHOWN ON PLANS.
 **BROWARD COUNTY PRODUCT APPROVALS ARE
 NOT ACCEPTED IN THIS OFFICE.
 16-CLARIFY WHY THERE IS NOT A THICKENED
 REINFORCED EDGE AT FOYER RECESS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 17-SHEET #2 OF 5: UPDATE/REVISE NOTE #3.
 SEE SEC. 2306.1 CITY AMENDMENTS TO FBC
 2001 FOR FASTENER SPACING @ ZONE 3.
 18-OWES $484.12 FOR UPDATED VALUE AND
 RADON FEES.
 19-ENGINEER OF RECORD TO PROVIDE ALL HIS
 INFORMATION AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES WHEN SUBMITTING
 INFORMATION FOR PUBLIC RECORDS.
 20-REVISE/UPDATE SURVEY. PROPERTY IS
 LOCATED ON FLOOD ZONE "B", NOT 'A8"
 AS PER LETTER OF MAP REVISION DATED
 DECEMBER, 3RD 1985.
  
  
 NOTES:
 **SEE COMMENTS BY THE OTHER TRADES.
 **PLEASE, RETURN SETS AFTER CORRECTIONS
 ARE DONE TO THE ORIGINAL CAD DRAWINGS
 TO EXPEDITE THE REVIEW PROCESS.