| Plan Review Notes For Permit 02120691 |
| Permit Number |
02120691 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-01-06 00:00:00 | BUILDING PROVISO: | | | 1)2304.5 CLEARENCE BETWEEN WOOD SIDING | | | & EARTH ON THE EXTERIOR OF A BUILDING | | | SHALL NOT BE LESS THAN 6" EXCEPT WHERE | | | SIDING, SHEATHING AND FRAME WALL ARE OF | | | APPROVED DURABLE WOOD OR APPROVED PRE- | | | SERVATIVE TREAATED WOOD. | | | THE CONCRETE SLAB THAT THE STUCCO | | | FINISHES AT WILL PULL MOISTURE BACK INTO | | | THE WALL A AIR GAP BETWEEN THE ORIGINAL | | | SLAB AND STUCCO WILL STOP THIS ACTION. | | | | | | 2) INDICATE WHAT TYPE OF STRAPS SHALL BE | | | USED FOR TIEING THE HEADERS TO THE VERTI | | | CAL FRAMING MEMBERS, REQUIRED BEFORE | | | FRAMING INSPECTION. | | | BUILDING PLAB REVIEW | | | JIM WITMER |
|