2003-01-06 00:00:00BUILDING PROVISO:
 1)2304.5 CLEARENCE BETWEEN WOOD SIDING
 & EARTH ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6" EXCEPT WHERE
 SIDING, SHEATHING AND FRAME WALL ARE OF
 APPROVED DURABLE WOOD OR APPROVED PRE-
 SERVATIVE TREAATED WOOD.
 THE CONCRETE SLAB THAT THE STUCCO
 FINISHES AT WILL PULL MOISTURE BACK INTO
 THE WALL A AIR GAP BETWEEN THE ORIGINAL
 SLAB AND STUCCO WILL STOP THIS ACTION.
  
 2) INDICATE WHAT TYPE OF STRAPS SHALL BE
 USED FOR TIEING THE HEADERS TO THE VERTI
 CAL FRAMING MEMBERS, REQUIRED BEFORE
 FRAMING INSPECTION.