| Date |
Text |
| 2003-01-28 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 FUEL GAS |
| | |
| | 1) SHT P1 SANITARY RISER DIAGRAM DOES |
| | NOT MEET CODE REQUIREMENTS. FIRST FLOOR |
| | SINK AND LAV ARE NOT VENTED. VERTICAL |
| | DRY VENT SHALL BE BETWEEN W/C AND SHOWER |
| | SECOND FLOOR, HORIZONTAL DRY VENTS ARE |
| | NOT APPROVED. (TUB VENT NOT REQUIRED, & |
| | W/C VENT CAN BE TAKEN OFF ON THE RISE TO |
| | WASH VENT. (SEE RED LINE CHANGES). |
| | 2) SHT P1 WATER RISER DIAGRAM, AIR CHAM- |
| | BERS ARE NOT APPROVED. WATER HAMMER ARR- |
| | ESTORS, REQUIRED BY SEC 604.9, AT WASH |
| | MACHINE, ICE MAKER, & DISHWASHER. |
| | 3) SHT P1 WATER RISER DIAGRAM, WATER |
| | HEATERS REQUIRE THERMAL EXPANSION CONT- |
| | ROL SECTION 607.3.2 - P/T DISCHARGE LINE |
| | SHALL DRAIN OUTSIDE WITH NO TRAPPED SEC- |
| | TIONS. SECTION 504.7.1 - 2ND FLOOR WATER |
| | HEATER SHALL HAVE AN EMERGENCY PAN PER |
| | SECTION 504.8. |
| | 4) SHT P1 A SEPARATE GAS PERMIT IS RE- |
| | QUIRED. SEE FOLLOWING GAS PERMIT APPLI- |
| | CATION REQUIREMENTS. |
| | A. SUBMIT AN ISOMETRIC DRAWING THAT |
| | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| | AND CORRESPONDING LENGTHS PER FBC-2001 |
| | FUEL GAS CODE. |
| | B. SHOW TYPE OF PIPING MATERIAL BEING |
| | INSTALLED, ALL PIPE SIZES, (AND THE EDH |
| | NUMBER OF CORRUGATED STAINLESS STEEL |
| | TUBING FOR EACH PIPE SIZE BEING USED. |
| | C. BTU LOAD OF EACH APPLIANCE AND THE |
| | TOTAL BTU LOAD ON THE SYSTEM. REFER TO |
| | THE FBC-2001 FUEL GAS CODE SECS. 401.8 |
| | THRU 402.5.2 AND TABLES 402(1) THRU |
| | 402(34). |
| | D. SHOW THE DISTANCE FROM THE POINT OF |
| | DELIVERY, (METER), TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| | FBC-2001 FUEL GAS CODE APPENDIX A - USE |
| | OF CAPACITY TABLES (A)(3). |
| | E. INDICATE THE DELIVERY PRESSURE (PSI) |
| | PER FBC-2001 FUEL GAS CODE SEC. 402.2. |
| | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. |
| | F) ALL GAS APPLIANCES SHALL BE LISTED |
| | FOR RESIDENTIAL USE ONLY. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 659-8096 EXT 8377 |