| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-02-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) ANSWER NOTED CONCERNING THE 20% | | | DISPROPORTIONAL COST FOR ACCESSIBILITY. | | | PLEASE ITEMISE ALL ACCESSIBILITY IMPROV- | | | MENTS AND SHOW COST OF EACH TO DETERMINE | | | HOW MUCH OF THE CONTRACT WAS SPENT FOR | | | THESE ITEMS. | | | 2) FROM PERVIOUS REVIEW: SHT P-2 WATER | | | HEATER DETAIL. THERMAL EXPANSION CONTROL | | | IS NOT ACHEIVED WITH A HEAT TRAP. EXPAN- | | | SION CONTROL REQUIRED BY SECTION 607.3.2 | | | IS ACCOMPLISHED WITH AN EXPANSION TANK. | | | PLEASE CHANGE DETAIL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|