| Plan Review Notes For Permit 02120463 |
| Permit Number |
02120463 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2003-09-22 00:00:00 | 09-22-03 | | | BUILDING PROVISO | | | PERMIT:02120463 | | | 712 PARK PLACE | | | | | | 1)1507.3.8. ASPHALT SHINGLES LOW | | | SLOPE ROOFING, UNDERLAYMENT APPLICATION | | | FOR ROOF SLOPES FROM 2:12 UP TO 4:12, | | | UNDERLAYMENT SHAL BE A MINIMUM OF TWO | | | LAYERS APPLIED AS FOLLOWS: | | | 1) STARTING AT THE EAVE, A 19-INCH | | | STRIP OF UNDERLAYMENT SHALL BE APPLIED | | | PARALLEL WITH THE EAVE AND FASTENED | | | SUFFICIENTLY TO STAY IN PLACE. | | | 2) STARTING AT THE EAVE, 36-INCH-WIDE | | | STRIPS OF UNDERLAYMENT FELT SHALL BE | | | APPLIED OVER LAPPING SUCCESSIVE SHEETS | | | 19 INCHES AND FASTENED SUFFICIENTLY TO | | | STAY IN PLACE. | | | | | | 2) PROVIDE A UPDATED NOTICE OF COMMENCE- | | | MENT. | | | | | | 3) PROVIDE PERMIT APPLICATION OR PROVIDE | | | A NEW COPY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|