| Date |
Text |
| 2003-07-10 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | REVISION SUBMITTED 6/17/03. |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) FBC* 104.1.5THE PROPOSED REVISIONS |
| | INCREASE THE SCOPE OF THE WORK.THE |
| | VALUE OF THE ADDITIONAL WORK SHALL BE |
| | DECLARED AND JUSTIFIED (E.G. WITH COPIES |
| | OF CONTRACTS) SO THAT THE ADDITIONAL |
| | PERMIT FEES DUE MAY BE DETERMINED. |
| | |
| | 2) FBC 11-4.24BREAK ROOM #3.REVISED |
| | SHEET A9 DOES NOT SHOW ANY DETAILS TO |
| | DEMONSTRATE THE ACCESSIBILITY OF THE |
| | SINK IN BREAK ROOM #3.AMEND THE PLANS. |
| | |
| | 3) FBC 2405.2THE FOLLOWING GLAZING IS |
| | IN A 'HAZARDOUS LOCATION' AND IS |
| | REQUIRED TO BE SAFETY GLASS SATISFYING |
| | THE REQUIREMENTS OF THE CONSUMER PRODUCT |
| | SAFETY COMMISSION 16, CODE OF FEDERAL |
| | REGULATIONS, PART 1201 (CPSC 16-CFR, |
| | PART 1201): |
| | - THE GLAZING IN REVISED DOORS 2A & 2B |
| | - THE GLAZING IN THE TWO NEW DOORS #25 |
| | - THE GLAZED SIDELITE PANELS ADJACENT |
| | EACH OF THE TWO NEW DOORS #25 |
| | AMEND/ANNOTATE THE DOOR AND WINDOW |
| | SCHEDULES TO DEMONSTRATE COMPLIANCE. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | TELEPHONE: (561) 805 6716ROBERT BROWN |
| | E-MAIL: [email protected] |