| Plan Review Notes For Permit 02111254 |
| Permit Number |
02111254 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2003-01-24 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-CLAY FLUE LININGS ARE TO BE USED ON | | | MASONRY CHIMNEYS. CHIMNEY SHOWN ON | | | PLANS IS WOOD FRAMED. THEREFORE, NEED | | | APPROPRIATE FLUE FOR FRAMED WALLS. | | | PROVIDE UL LISTING AND SPECS AS REQ'D | | | BY SEC. 2804.4 FBC 2001. | | | 2-MATERIALS USED FOR CHIMNEY EXTENSION | | | AND FLUE EXTENSION MUST BE IN CONFOR- | | | MANCE WITH EXISTING FIREPLACE SPECS & | | | UL LISTING. PROVIDE COMPLETE INFORMA- | | | TION TO VERIFY THAT PROPOSED CHIMNEY & | | | FLUE EXTENSION ARE ADEQUATE AND SAFE | | | TO USE WITHOUT AFFECTING THE FIREPLACE | | | PERFORMANCE. PROVIDE INFORMATION | | | FOR MECHANICAL PLANS EXAMINER FOR | | | APPROVAL PRIOR TO INSTALLATION AND | | | CONSTRUCTION. | | | 3-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS PRIOR TO INSTALLATION. (TWO) | | | 4-PROVIDE 2 COPIES OF PRODUCT APPROVALS | | | FOR: A)ROOF TILE. B)FRENCH DOOR. |
|