Plan Review Notes For Permit 02111043
Permit Number 02111043
Review Stop P
Sequence Number 1
Notes
Date Text
2002-12-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) AHT A1.1 ALL ABANDONED PIPES TO BE
 CAPPED OFF SHALL BE INSPECTED PRIOR TO
 COVERING.
 2) SHT B1.1 DRY HORIZONTAL VENTS ARE NOT
 ALLOWED. SECTION 905.3 (PAST LAST FLOOR
 SINK)
 3) PLEASE SUBMIT A SANITARY RISER DIA-
 GRAM AND A WATER RISER DIAGRAM. SEE SEC.
 604.9
 4) PER SEC. 11-4.1.6(2) UP TO 20 PERCENT
 OVER CONTRACT SHALL BE SPENT FOR ALTER-
 ATIONS TO BRING EXISTING ACCESSIBILITY
 CONDITIONS UP TO PRESENT DAY CODE.
 PLEASE INDICATE HOW THAT $50,000 WILL BE
 SPENT. PRESENT TOILET STALLS DO NOT MEET
 CODE PER FIGURE 30E.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377