2002-12-19 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-CLARIFY DETAIL S21. PROVIDE CLEAR FOR
 COLUMN BETWEEN GARAGE AND STAIRWAY
 SHOWING HOW IS THE TOP CONNECTOR
 RECEIVING THE TWO GIRDER TRUSSES. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-REVISE CONNECTOR TC-1 SPECIFIED AT
 FRONT ELEVATION ON ROOF FRAMING PLAN.
 NEED WOOD TO WOOD CONNECTOR FOR FRAMED
 WALL. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
 5-PROVIDE SPECIFICATIONS ON STRUCTURAL
 WALL SECTIONS FOR FIRECUT REQUIREMENTS
 TO COMPLY WITH SEC. 2305.4 FBC 2001.
 6-REVISE STAIRS TOP DETAIL ON SHEET A-4
 TO MATCH FRAMING PLAN AND SPECIFY
 FIREBLOCKING. SEC. 2305.1.4 FBC 2001.