Plan Review Notes
Plan Review Notes For Permit 02110524
Permit Number 02110524
Review Stop P
Sequence Number 1
Notes
Date Text
2002-12-05 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
  
 1) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE 410.1, IF A WATER
 COOLER IS SUBSTITUTED IT SHALL BE ARI-
 1010 COMPLIANT AND MANUF. INFO IS REQD.
 2) SEPARATE GAS PERMIT IS REQUIRED. THE
 FOLLOWING INFORMATION IS REQUIRED FOR
 APPLICATION OF GAS PERMIT.
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 GAS CODE.
 2. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC-2001
 FUEL GAS CODE SEC. 402.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377