| Date |
Text |
| 2002-12-18 00:00:00 | BUILDING DENIED |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | INDICATE THE IMPORTANCE FACTOR AND THE |
| | INTERNAL PRESSURE COEFFICIENT ON THE A |
| | PLANS. |
| | |
| | 3) INDICATE ACCESS TO ATTIC SPACE AS |
| | REQUIRED BY FBC 2309.6. |
| | |
| | 4) REVISE NOTE 1 ON SHEET 1 TO COMPLY |
| | WITH CITY OF WPB AMENDMENTS TO FBC TABLE |
| | 2306.1 FOR ROOF SHAETHING NAILING |
| | REQUIREMENTS. |
| | |
| | 5) REVISE NOTE 2 ON SHEET 1, 3/8" RIB |
| | LATH IS REQUIRED TO BE NAILED AT EVERY |
| | RIB (4") PER FBC 2504.2.2 AND ASTM C1063 |
| | 710.1.1. |
| | |
| | 6) CLARIFY WALL SECTION ON SHEET 2 TO |
| | INDICATE THE BOTTOM OF FOOTING TO BE A |
| | MINIMUM OF 12" BELOW FINAL GRADE AND THE |
| | FINISH FLOOR TO BE A MINIMUM OF 4" ABOVE |
| | FINAL GRADE. SEE FBC 1804.1.3 AND CITY |
| | AMENDMENTS 1804.1.7. |
| | |
| | 7) INDICATE FIREBLOCKING ON THE WALL |
| | SECTION ON SHEET 2 WHERE THE FURRED |
| | SPACE ON THE WALL MEETS THE CEILING. |
| | SEE FBC 2305.1.4. |
| | |
| | 8) THE FOUNDATION PLAN ON SHEET 3 IS |
| | MISSING THE VERTICAL REINFORCEMENT AT |
| | THE LEFT SIDE OF THE GARAGE. PLEASE |
| | CORRECT. |
| | |
| | 9) PROVIDE SECTION THROUGH SLAB AT AT |
| | THE 6" STEP IN GARAGE. |
| | |
| | 10) PROVIDE A DETAIL OF THE ARCHES AT |
| | THE FRONT PORCH INDICATING HOW THEY ARE |
| | TO BE CONSTRUCTED. |
| | |
| | 11) THE OWNER/AGENT IS REQUIRED TO SIGN |
| | AND DATE THE ENERGY CALC. FORM. PROVIDE |
| | TWO COPIES OF ENERGY CALCULATIONS. |
| | |
| | 12)PROVIDE (2) COPIES OF A KEY PLAN AND |
| | INSTALLATION SCHEDULE FOR STORM PANELS |
| | INDICATING THE SPECIFIC TYPES OF ANCHORS |
| | AND SPACING. |
| | |
| | 13) PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - EXTERIOR DOORS |
| | - OVERHEAD GARAGE DOOR |
| | - ROOF COVERING |
| | |
| | 14)STRUCTURE IS LOCATED ON ALAMANDA ROAD |
| | NOT AVENUE. PLEASE CORRECT SITE PLAN. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |