| 2002-12-02 00:00:00 | THE MINIMUM CONSTRUCTION TYPE FOR THIS |
| | BULDING IS TYPE V 1 HOUR PROTECTED OR |
| | TYPE V FIRE SPRINKLERED.PLEASE NOTE |
| | THE PARTICULAR EXISTING CONDITION AT |
| | TIME OF PERMIT APPLICATION OR METHOD OF |
| | COMPLIANCE TO BE ESTABLISHED. |
| | |
| | THE PERMIT PLANS MUST HAVE THE MINIMUM |
| | DESIGN INFORMATION CONTAINED IN FBC |
| | 104. 3.1.1 AND FBC 1606.1.7. |
| | |
| | SHEET A1 DOES NOT SHOW THE SPACING OF |
| | THE 4X4 STEEL COLUMNS. |
| | |
| | SECTIONS TAKEN AS B AND C ON SHEET A1 |
| | ARE NOT INCLUDED WITH THE PLANS. |
| | |
| | SHOW A DETAIL FOR THE INSTALLATION OF |
| | THE NEW PAD FOOTINGS IN RELATION TO THE |
| | EXISTING WALL FOOTINGS, PARTICLARLY THE |
| | ONES THAT WILL BE ECCENTRICALLY LOADED. |
| | INCLUDE THE HEIGHT OF THE TOP OF THE |
| | PADS RELATIVE TO THE FINISH FLOOR. |
| | |
| | SHEET A2, SHOW A DETAIL FOR THE |
| | TRANSITION OF THE W12X27 BEAM TO THE |
| | 8X8X1 ANGLE. ALSO, THE STEEL COLUMN |
| | DETAIL DOES NOT PROVIDE FOR ATTACHMENT |
| | TO THE W12X27 BEAM. |
| | |
| | SHEET A3.SHOW HOW HANDICAP VERTICAL |
| | ACCESSIBILITY WILL BE ACCOMPLISHED. |
| | SEE FBC 11-4.1.6 (1) (F) |
| | |
| | SHOW A CONSTRUCTION DETAIL FOR THE |
| | INTERIOR STAIRS. |
| | |
| | SHOW ALL OF THE STRUCTURAL DESIGN LOADS |
| | ASSUMED, IE FLOOR, STAIRS, HAND AND |
| | GUARD RAILS. |
| | |
| | PROVIDE A BEARING CONNECTION DETAIL FOR |
| | THE BAR JOISTS. |
| | |
| | SECTION D/3.SHOW THE REINFORCING |
| | DETAIL FOR THE CANTILEVERED LANDING. |
| | |
| | SHOW HOW THE EXTERIOR GLAZING WILL |
| | RESIST HURRICANE MISSILE IMPACT.SEE |
| | FBC 1606.1.4 |
| | |
| | THE INTERIOR STAIRS ARE REQUIRED BY FBC |
| | 1006.1.1 TO BE ENCLOSED WITH FIRE RATED |
| | CONSTRUCTION AND TO PROVIDE A PROTECTED |
| | PATH OF EGRESS TO THE EXTERIOR OF THE |
| | BUILDING AS PROVIDED FOR IN FBC 1010. |
| | |
| | THE EXTERIOR STAIRS MUST MEET ALL OF THE |
| | REQUIREMENTS OF FBC 1006.2. |
| | |
| | SHOW THE FLOOR TO CEILING HEIGHTS OF THE |
| | FIRST AND SECOND FLOORS. |
| | |
| | WHAT IS THE NATURE AND QUANTITY OF THE |
| | COMMODITIES TO BE STORED IN THIS SPACE? |
| | |
| | THE ADDITIONAL BUILDING AREA TO BE |
| | ADDED IS SUBJECT TO IMPACT FEES |
| | COLLECTED BY THE COUNTY.BEFORE A |
| | PERMIT TO CONSTRUCT MAY BE ISSUED |
| | IMPACT FEES MUST BE PAID TO THE COUNTY, |
| | THE PERMIT PLANS STAMPED BY THAT OFFICE |
| | AND A COPY OF THE PAID RECEIPT ATTACHED |
| | TO THE PERMIT APPLICATION.CALL |
| | 561-233-5025 FOR MORE INFORMATION. |
| | |
| | ALL PLANS SUBMITTED FOR PUBLIC RECORD, |
| | INCLUDING THE SURVEY/SITE PLAN, MUST BE |
| | SIGNED AND SEALED BY THE DESIGNER OF |
| | RECORD.SEE FBC 104.2.2. |